Fluid-attenuated inversion recovery MR imaging: Identification of protein concentration thresholds for CSF hyperintensity

被引:86
作者
Melhem, ER
Jara, H
Eustace, S
机构
[1] Department of Radiology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, 88 E. Newton St.
关键词
D O I
10.2214/ajr.169.3.9275912
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Using human volunteers and phantoms emulating CSF, we analyzed the effects of varying protein concentration on the signal intensity of saline solution. Also, for different fluid-attenuated inversion recovery (FLAIR) sequences, we compared protein concentration thresholds above which the signal from these solutions becomes hyperintense to that from brain parenchyma. SUBJECTS AND METHODS. Nine albumin solutions of varying concentrations (3.9 mg/dl to 2500 mg/dl) were imaged using fast FLAIR MR sequences (TR, 6000 msec; inversion time, 1730 msec; echo train length, 20) at different effective TEs (110, 150, 200, and 250 msec). The brains of five healthy volunteers were imaged using the same sequences. Plots of signal-to-noise ratios from the different albumin solutions versus albumin concentration were generated and correlated with average signal-to-noise ratios from brain parenchyma and CSF. RESULTS. We saw a gradual increase in signal-to-noise ratios from the albumin solutions as a function of albumin concentration, As the effective TE increased, the point of intersection between the plots and the average signal-to-noise ratio from brain parenchyma occurred at lower albumin concentrations. CONCLUSION. FLAIR MR imaging is potentially useful to evaluate pathologic conditions that increase CSF protein concentration, Using phantoms and healthy volunteers, we defined a protein concentration threshold above which the signal from saline solutions becomes hyperintense to that from brain parenchyma. This threshold depends on the effective TE used in the FLAIR sequence and is 250 mg/dl for an effective TE of 110 msec, 125 mg/dl for 150 msec, 110 mg/dl for 200 msec, and 95 mg/dl for 250 msec.
引用
收藏
页码:859 / 862
页数:4
相关论文
共 14 条
  • [1] MR IMAGING IS HIGHLY SENSITIVE FOR ACUTE SUBARACHNOID HEMORRHAGE - NOT
    ATLAS, SW
    [J]. RADIOLOGY, 1993, 186 (02) : 319 - 322
  • [2] STIR MR IMAGING OF THE ORBIT
    ATLAS, SW
    GROSSMAN, RI
    HACKNEY, DB
    GOLDBERG, HI
    BILANIUK, LT
    ZIMMERMAN, RA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 1025 - 1030
  • [3] EFFECT OF METHEMOGLOBIN FORMATION ON THE MR APPEARANCE OF SUBARACHNOID HEMORRHAGE
    BRADLEY, WG
    SCHMIDT, PG
    [J]. RADIOLOGY, 1985, 156 (01) : 99 - 103
  • [4] MR APPEARANCE OF HEMORRHAGE IN THE BRAIN
    BRADLEY, WG
    [J]. RADIOLOGY, 1993, 189 (01) : 15 - 26
  • [5] MR IMAGING OF THE LIVER USING SHORT TI INVERSION RECOVERY SEQUENCES
    BYDDER, GM
    STEINER, RE
    BLUMGART, LH
    KHENIA, S
    YOUNG, IR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (06) : 1084 - 1089
  • [6] MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE
    BYDDER, GM
    YOUNG, IR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 659 - 675
  • [7] DECOENE B, 1992, AM J NEURORADIOL, V13, P1555
  • [8] SHORT-TI INVERSION-RECOVERY PULSE SEQUENCE - ANALYSIS AND INITIAL EXPERIENCE IN CANCER IMAGING
    DWYER, AJ
    FRANK, JA
    SANK, VJ
    REINIG, JW
    HICKEY, AM
    DOPPMAN, JL
    [J]. RADIOLOGY, 1988, 168 (03) : 827 - 836
  • [9] Grossman R I, 1986, Acta Radiol Suppl, V369, P56
  • [10] USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN
    HAJNAL, JV
    BRYANT, DJ
    KASUBOSKI, L
    PATTANY, PM
    DECOENE, B
    LEWIS, PD
    PENNOCK, JM
    OATRIDGE, A
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) : 841 - 844