A comparison of assay performance measures in screening assays:: Signal window, Z′ factor, and assay variability ratio

被引:166
作者
Iversen, PW [1 ]
Eastwood, BJ [1 ]
Sittampalam, GS [1 ]
Cox, KL [1 ]
机构
[1] Eli Lilly & Co, Lilly Res Labs, Indianapolis, IN 46285 USA
关键词
signal window; Z ' factor; assay variability ratio; assay validation;
D O I
10.1177/1087057105285610
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this article, the authors compare the assay performance measures, signal window, Z' factor, and assay variability ratio. They exanl ine their mathematical formulae for similarities and differences, describe their statistical sampling properties using the results of a Computer simulation, and illustrate their use with example data. Based on these results, the authors recommend the Z' factor as a preferred measure of assay performance for screening assays and point out that none of these measures are adequate for characterizing concentration-response assays.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 6 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   The minimum significant ratio: A statistical parameter to characterize the reproducibility of potency estimates from concentration-response assays and estimation by replicate-experiment studies [J].
Eastwood, BJ ;
Farmen, MW ;
Iversen, PW ;
Craft, TJ ;
Smallwood, JK ;
Garbison, KE ;
Delapp, NW ;
Smith, GF .
JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (03) :253-261
[3]   Design of signal windows in high throughput screening assays for drug discovery [J].
Sittampalam, GS ;
Iversen, PW ;
Boadt, JA ;
Kahl, SD ;
Bright, S ;
Zock, JM ;
Janzen, WP ;
Lister, MD .
JOURNAL OF BIOMOLECULAR SCREENING, 1997, 2 (03) :159-169
[4]   Automated assay optimization with integrated statistics and smart robotics [J].
Taylor, PB ;
Stewart, FP ;
Dunnington, DJ ;
Quinn, ST ;
Schulz, CK ;
Vaidya, KS ;
Kurali, E ;
Lane, TR ;
Xiong, WFC ;
Sherrill, TP ;
Snider, JS ;
Terpstra, ND ;
Hertzberg, RP .
JOURNAL OF BIOMOLECULAR SCREENING, 2000, 5 (04) :213-225
[5]   A simple statistical parameter for use in evaluation and validation of high throughput screening assays [J].
Zhang, JH ;
Chung, TDY ;
Oldenburg, KR .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (02) :67-73
[6]   Confirmation of primary active substances from high throughput screening of chemical and biological populations: A statistical approach and practical considerations [J].
Zhang, JH ;
Chung, TDY ;
Oldenburg, KR .
JOURNAL OF COMBINATORIAL CHEMISTRY, 2000, 2 (03) :258-265