Uptake rates of alkylphenols, PAHs and carbazoles in semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS)

被引:89
作者
Harman, C. [1 ,2 ]
Tollefsen, K-E. [1 ]
Boyum, O. [1 ]
Thomas, K. [1 ]
Grung, M. [1 ]
机构
[1] Oslo Ctr Interdisciplinary Environm & Social Res, Norwegian Inst Water Res, NO-0349 Oslo, Norway
[2] Univ Oslo, Dept Chem, Oslo, Norway
关键词
passive sampling; uptake kinetics; nonylphenol; calibration; offshore oil industry; monitoring;
D O I
10.1016/j.chemosphere.2008.04.091
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive sampling devices provide a useful contribution to the monitoring of contaminants in the aquatic environment. However, calibration data needed for the calculation of water concentrations from sampler accumulations are restricted to a limited number of compound classes. Thus uptake of a range of alkylated phenols (AP), polycyclic aromatic hydrocarbons (PAH) and carbazoles was determined for semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS) using a flow through exposure system. Sampling rates ranged from 0.02 to 0.26 1 d(-1) for POCIS and 0,02 to 13.83 1 d(-1) for SPMDs. Observed SPMD uptake was also compared to that predicted by an empirical model including the use of performance reference compounds (PRCs). Predicted sampling rates did not differ by more than a factor of 1.3 from experimental values for PAR providing further evidence that the PRC approach can be successfully used to determine in situ sampling rates for these compounds. Experimental sampling rates for AP in SPMDs were, however, much lower than predicted. This discrepancy was too large to be explained by small uncertainties in the calibration system or in the calculations. Based on these data we conclude that while hydrophobic AP are accumulated by SPMDs their partitioning cannot be predicted from their log K-ow using current methods. Due to this lower than expected uptake, sampling rates were only higher in SPMDs than POCIS in the range of log K-ow > 5.0. Simultaneous deployment of both sampler types allows the study of compounds with a broad range of physicochemical properties. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1510 / 1516
页数:7
相关论文
共 74 条
[1]   PARTITIONING OF ALKYLPHENOLS AND ALKYLPHENOL POLYETHOXYLATES BETWEEN WATER AND ORGANIC-SOLVENTS [J].
AHEL, M ;
GIGER, W .
CHEMOSPHERE, 1993, 26 (08) :1471-1478
[2]  
Alvarez D. A., 1999, THESIS U MISSOURI CO
[3]   Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream [J].
Alvarez, DA ;
Stackelberg, PE ;
Petty, JD ;
Huckins, JN ;
Furlong, ET ;
Zaugg, SD ;
Meyer, MT .
CHEMOSPHERE, 2005, 61 (05) :610-622
[4]   Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments [J].
Alvarez, DA ;
Petty, JD ;
Huckins, JN ;
Jones-Lepp, TL ;
Getting, DT ;
Goddard, JP ;
Manahan, SE .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2004, 23 (07) :1640-1648
[5]  
Alvarez DA, 2007, COMP ANAL C, V48, P171, DOI 10.1016/S0166-526X(06)48008-9
[6]  
[Anonymous], 1993, LOGKOW DATABANK EVAL
[7]  
Arukwe A, 1997, ENVIRON TOXICOL CHEM, V16, P2576, DOI [10.1002/etc.5620161220, 10.1897/1551-5028(1997)016&lt
[8]  
2576:XASBEI&gt
[9]  
2.3.CO
[10]  
2]