Investigation of low frequency drift in fMRI signal

被引:236
作者
Smith, AM
Lewis, BK
Ruttimann, UE
Ye, FQ
Sinnwell, TM
Yang, YH
Duyn, JH
Frank, JA
机构
[1] NIMH, NIH, Bethesda, MD 20892 USA
[2] NIAAA, Lab Diagnost Radiol Res, Bethesda, MD USA
关键词
functional magnetic resonance imaging (fMRI); low frequency drift; BOLD; artifacts;
D O I
10.1006/nimg.1999.0435
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Low frequency drift (0.0-0.015 Hz) has often been reported in time series fMRI data. This drift has often been attributed to physiological noise or subject motion, but no studies have been done to test this assumption. Time series T-2*-weighted volumes were acquired on two clinical 1.5 T MRI systems using spiral and EPI readout gradients from cadavers, a normal volunteer, and nonhomogeneous and homogeneous phantoms. The data were tested for significant differences (P = 0.001) from Gaussian noise in the frequency range 0.0-0.015 Hz. The percentage of voxels that were significant in data from the cadaver, normal volunteer, nonhomogeneous and homogeneous phantoms were 13.7-49.0%, 22.1-61.9%, 46.4-68.0%, and 1.10%, respectively. Low frequency drift was more pronounced in regions with high spatial intensity gradients. Significant drifting was present in data acquired from cadavers and nonhomogeneous phantoms and all pulse sequences tested, implying that scanner instabilities and not motion or physiological noise may be the major cause of the drift. (C) 1999 Academic Press.
引用
收藏
页码:526 / 533
页数:8
相关论文
共 23 条
[1]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[2]  
BIRN RM, 1997, P ISMRM 5 ANN M VANC, P1913
[3]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[4]   Hypercapnia reversibly suppresses low-frequency fluctuations in the human motor cortex during rest using echo-planar MRI [J].
Biswal, B ;
Hudetz, AG ;
Yetkin, FZ ;
Haughton, VM ;
Hyde, JS .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (03) :301-308
[5]   Statistical methods of estimation and inference for functional MR image analysis [J].
Bullmore, E ;
Brammer, M ;
Williams, SCR ;
Rabehesketh, S ;
Janot, N ;
David, A ;
Mellers, J ;
Howard, R ;
Sham, P .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :261-277
[6]   Noise suppression digital filter for functional magnetic resonance imaging based on image reference data [J].
Buonocore, MH ;
Maddock, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :456-469
[7]  
EDELSTEIN WA, 1997, P ISMRM 5 ANN M VANC, P1472
[8]  
Finelli DA, 1997, AM J NEURORADIOL, V18, P147
[9]   ANALYSIS OF FMRI TIME-SERIES REVISITED [J].
FRISTON, KJ ;
HOLMES, AP ;
POLINE, JB ;
GRASBY, PJ ;
WILLIAMS, SCR ;
FRACKOWIAK, RSJ ;
TURNER, R .
NEUROIMAGE, 1995, 2 (01) :45-53
[10]  
GENOVESE CR, 1997, P ISMRM 5 ANN M VANC