Accuracy and reliability of remote retinopathy of prematurity diagnosis

被引:95
作者
Chiang, MF
Keenan, JD
Starren, J
Du, YLE
Schiff, WM
Barile, GR
Li, J
Johnson, RA
Hess, DJ
Flynn, JT
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Ophthalmol, New York, NY 10032 USA
[2] Columbia Univ, Coll Phys & Surg, Dept Radiol, New York, NY 10032 USA
[3] Albert Einstein Coll Med, Dept Epidemiol & Populat Hlth, New York, NY USA
[4] Jackson Mem Hosp, Dept Pediat Nursing, Miami, FL 33136 USA
[5] Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
D O I
10.1001/archopht.124.3.322
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To determine the accuracy and reliability of retinopathy of prematurity (ROP) diagnosis using remote review of digital images by 3 masked ophthalmologist readers. Methods: An atlas was compiled of 410 retinal photographs from 163 eyes of 64 low-birth-weight infants taken using a wide-angle digital fundus camera. All the images were independently reviewed by 3 readers, and the diagnosis in each eye was classified into 1 of 4 ordinal categories: no ROP, mild ROP, type 2 prethreshold ROP, or ROP requiring treatment. Findings were compared with a reference standard of dilated indirect ophthalmoscopy with scleral depression performed by an experienced pediatric ophthalmologist. Results: Sensitivities/specificities of the diagnosis of any ROP were 0.845/0.910 for the first reader, 0.816/0.955 for the second reader, and 0.864/0.493 for the third reader. Sensitivities/specificities of the diagnosis of ROP requiring treatment were 0.850/0.960 for the first reader, 0.850/0.973 for the second reader, and 0.900/0.953 for the third reader. When ROP was classified into ordinal categories, the overall weighted kappa for interreader reliability was 0.743. Intrareader reliability for detection of low-risk pre-threshold ROP or worse was 100% for all readers. Conclusion: The accuracy, interreader reliability, and intrareader reliability of remote diagnosis of clinically relevant ROP based on digital imaging are substantial.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 29 条
[1]  
[Anonymous], 1988, Arch Ophthalmol, V106, P471
[2]  
[Anonymous], 1991, Ophthalmology, V98, P786
[3]   Telemedicine: A new health care delivery system [J].
Bashshur, RL ;
Reardon, TG ;
Shannon, GW .
ANNUAL REVIEW OF PUBLIC HEALTH, 2000, 21 :613-637
[4]   Stereo nonmydriatic digital-video color retinal imaging compared with early treatment diabetic retinopathy study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy [J].
Bursell, SE ;
Cavallerano, JD ;
Cavallerano, AA ;
Clermont, AC ;
Birkmire-Peters, D ;
Aiello, LP ;
Aiello, LM .
OPHTHALMOLOGY, 2001, 108 (03) :572-585
[6]   Telemedicine approach to screening for severe retinopathy of prematurity - A pilot study [J].
Ells, AL ;
Holmes, JM ;
Astle, WF ;
Williams, G ;
Leske, DA ;
Fielden, M ;
Uphill, B ;
Jennett, P ;
Hebert, M .
OPHTHALMOLOGY, 2003, 110 (11) :2113-2117
[7]  
Elsas FJ, 2001, ARCH OPHTHALMOL-CHIC, V119, P1110
[8]  
Field MJ., 1996, TELEMEDICINE GUIDE A
[9]  
Fierson WM, 2001, PEDIATRICS, V108, P809, DOI 10.1542/peds.108.3.809
[10]   Clinical evaluation of patients with diabetic retinopathy - Accuracy of the Inoveon Diabetic Retinopathy-3DT System [J].
Fransen, SR ;
Leonard-Martin, TC ;
Feuer, WJ ;
Hildebrand, PL .
OPHTHALMOLOGY, 2002, 109 (03) :595-601