Improvement of MRI-functional measurement with automatic movement correction in native and transplanted kidneys

被引:36
作者
de Senneville, Baudouin Denis [1 ]
Mendichovszky, Iosif Alexandru [2 ]
Roujol, Sebastien [1 ,3 ]
Gordon, Isky [2 ]
Moonen, Chrit [1 ]
Grenier, Nicolas [1 ,4 ]
机构
[1] Univ Bordeaux 2, CNRS, UMR 5231, Lab Mol & Funct Imaging Physiol Therapy,ERT, 146 Rue Leo Saignat,Case 117, F-33076 Bordeaux, France
[2] UCL Inst Child Hlth, London, England
[3] Ecole Natl Super Elect Informat & Radiocommun Bor, Talence, France
[4] Grp Hosp Pellegrin, Serv Imagerie Diagnost & Intervent Adulte, Bordeaux, France
关键词
MRI-functional measurement; kidney perfusion; glomerular filtration rate; movement correction;
D O I
10.1002/jmri.21515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To improve 2D software for motion correction of renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and to evaluate its effect using the Patlak-Rutland model. Materials and Methods: A subpixel-accurate method to correct for kidney motion during DCE-MRI was evaluated on native and transplanted kidneys using data from two different institutions with different magnets and protocols. The Patlak-Rutland model was used to calculate glomerular filtration rate (GFR) on a voxel-by-voxel basis providing mean ((K) over bar (p)) and uncertainty ((sigma) over bar (K-p))values for GFR. Results: In transplanted kidneys, average absolute variation of (K) over bar (p), was 6.4% +/- 4.8% (max = 16.6%). In native kidneys average absolute variation of (K) over bar (p), was 12.11% +/- 6.88% (max = 25.6%) for the right and 11.6% +/- 6% (max = 20.8%) for the left. Movement correction showed an average reduction of (sigma) over bar (K-p) of 6.9% +/- 6.6% (max = 21.4%) in transplanted kidneys, 30.9% +/- 17.6% (max = 60.8%) for the right native kidney, and 31.8% +/- 14% (max = 55.3%) for the left kidney. Conclusion: The movement correction algorithm showed improved uncertainty on GFR computation for both native and transplanted kidneys despite different spatial resolution from the different MRI systems and different levels of signal-to-noise ratios on DCE-MRI.
引用
收藏
页码:970 / 978
页数:9
相关论文
共 20 条
[1]
Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[2]
Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects [J].
Buckley, David L. ;
Shurrab, Ala'a E. ;
Cheung, Ching M. ;
Jones, Andrew P. ;
Mamtora, Hari ;
Kalra, Philip A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1117-1123
[3]
Comparison of the performance of tracer kinetic model-driven registration for dynamic contrast enhanced MRI using different models of contrast enhancement [J].
Buonaccorsi, Giovanni A. ;
Roberts, Caleb ;
Cheung, Sue ;
Watson, Yvonne ;
O'Connor, James P. B. ;
Davies, Karen ;
Jackson, Alan ;
Jayson, Gordon C. ;
Parker, Geoff J. M. .
ACADEMIC RADIOLOGY, 2006, 13 (09) :1112-1123
[4]
de Zwart JA, 2001, MAGNET RESON MED, V45, P128, DOI 10.1002/1522-2594(200101)45:1<128::AID-MRM1017>3.0.CO
[5]
2-M
[6]
SEMIAUTOMATED ROI ANALYSIS IN DYNAMIC MR STUDIES .1. IMAGE-ANALYSIS TOOLS FOR AUTOMATIC CORRECTION OF ORGAN DISPLACEMENTS [J].
GERIG, G ;
KIKINIS, R ;
KUONI, W ;
VONSCHULTHESS, GK ;
KUBLER, O .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) :725-732
[7]
Movement correction of the kidney in dynamic MRI scans using FFT phase difference movement detection [J].
Giele, ELW ;
de Priester, JA ;
Blom, JA ;
den Boer, JA ;
van Engelshoven, JMA ;
Hasman, A ;
Geerlings, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :741-749
[8]
GONZALES RC, 2001, DIGITAL IMAGE PROCES, P578
[9]
Fast method for correcting image misregistration due to organ motion in time-series MRI data [J].
Gupta, SN ;
Solaiyappan, M ;
Beache, GM ;
Arai, AE ;
Foo, TKF .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :506-514
[10]
Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique [J].
Hackstein, N ;
Heckrodt, J ;
Rau, WS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :714-725