Comparison of two alternative methods for CD4+ T-cell determination (Coulter manual CD4 count and CyFlow) against standard dual platform flow cytometry in Uganda

被引:20
作者
Karcher, H
Bhning, D
Downing, R
Mashate, S
Harms, G
机构
[1] GTZ PMTCT Project, Inst Trop Med Berlin, German Tech Cooperat, D-14050 Berlin, Germany
[2] Univ Med Berlin, Charite, Div Int Hlth, Inst Social Med, Berlin, Germany
[3] Ctr Dis Control & Prevent, Uganda Virus Res Inst, Entebbe, Uganda
[4] GTZ PMTCT Project, Ft Portal, Uganda
[5] Univ Med Berlin, Charite, Inst Trop Med, Berlin, Germany
关键词
cyto-spheres; CyFlow; CD4(+) T-cell determination; resource-limited setting; volumetric single platform flow cytometry; PMTCT plus;
D O I
10.1002/cyto.b.20093
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: In this study we evaluated alternative CD4(+) T-cell counting methods in clients of a PMTCT Programme in rural Uganda. Methods: The Coulter Manual CD4 Count method for CD4(+) T-cell enumeration (Cyto-Spheres) and an automated method (volumetric, single-platform flow cytometry; CyFlow) were compared with a standard, dual-platform flow cytometry protocol (OPFC, FACScan). Results: Correlation and precision of agreement were higher for the CyFlow method (r = 0.929 and q = 0.08) when compared to DPFC than for the Cyto-Spheres method (r = 0.725 and eta = 0.3). Multiple linear regression analysis showed that CD4(+) cell counts by the CyFlow method were a stronger predictor for results of DPFC than those of the Cyto-Spheres method (r(2) = 0.864 and r(2) = 0.552, respectively). When compared to DPFC the CyFlow method generated higher CD4+ cell counts than the Cyto-Spheres method, as expressed by a higher median and mean difference (+70 and +90 cells for CyFlow, +28 and -1.4 cells for Cyto-Spheres). Conclusion: Both, the manual Cyto-Spheres method and the CyFlow method can be used for the enumeration of CD4(+) cells in resource-limited settings. Under supervised conditions, the CyFlow method produced results more consistent with the reference method than the Cyto-Spheres method. (c) 2006 international Society for Analytical Cytology.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 2003, SCAL ANT THER RES LT
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BOHNING D, SOME GEN POINTS WHEN
[4]   A MANUAL BEAD ASSAY FOR THE DETERMINATION OF ABSOLUTE CD4(+) AND CD8(+) LYMPHOCYTE COUNTS IN HUMAN IMMUNODEFICIENCY VIRUS-INFECTED INDIVIDUALS [J].
CARELLA, AV ;
MOSS, MW ;
PROVOST, V ;
QUINN, TC .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1995, 2 (05) :623-625
[5]  
Cassens U, 2004, ANTIVIR THER, V9, P395
[6]  
DEWIT TR, ACCESS HAART DEV WOR
[7]   Successful implementation of a low-cost method for enumerating CD4+ T lymphocytes in resource-limited settings:: the ANRS 12-26 study [J].
Diagbouga, S ;
Chazallon, C ;
Kazatchkine, MD ;
de Perre, PV ;
Inwoley, A ;
M'Boup, S ;
David, MP ;
Ténin, AT ;
Soudré, R ;
Aboulker, JP ;
Weiss, L .
AIDS, 2003, 17 (15) :2201-2208
[8]   Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries [J].
Didier, JM ;
Kazatchkine, MD ;
Demouchy, C ;
Moat, C ;
Diagbouga, S ;
Sepulveda, C ;
Di Lonardo, AM ;
Weiss, L .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2001, 26 (02) :193-195
[9]  
FERREIRA OC, 1994, J ACQ IMMUN DEF SYND, V7, P1224
[10]   DETERMINATION OF CD4+ AND CD8+ LYMPHOCYTES WITH THE CYTOSPHERE ASSAY - A COMPARATIVE-STUDY WITH FLOW-CYTOMETRY AND THE IMMUNOALKALINE PHOSPHATASE METHOD [J].
GERNOW, A ;
LISSE, IM ;
BOTTIGER, B ;
CHRISTENSEN, L ;
BRATTEGAARD, K .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1995, 76 (02) :135-141