Assessment of Dowex 1-X8-based anion-exchange procedures for the separation and determination of ruthenium, rhodium, palladium, iridium, platinum and gold in geological samples by inductively coupled plasma mass spectrometry

被引:130
作者
Jarvis, I [1 ]
Totland, MM [1 ]
Jarvis, KE [1 ]
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,CTR ANALYT RES ENVIRONM,NERC,ICP MS FACIL,ASCOT SL5 7TE,BERKS,ENGLAND
关键词
platinum group element; gold; cation exchange chromatography; geological sample; inductively coupled plasma mass spectrometry;
D O I
10.1039/a606169i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Synthetic multielement solutions of the platinum group metals (PGE: Ru; Rh; Pd; Ir; Pt) and gold, with analysis by ICP-AES and ICP-MS, have been used to study the behaviour of the precious metals on Dowex 1-X8 resin, Simple solutions of precious-metal chlorocomplexes showed near-complete adsorption (>99%) of most elements, and only minor breakthrough of Ru and Ru (approximate to 5%). Solutions pre-treated with acid mixtures typically used to decompose geological samples, demonstrated that perchloric acid adversely affects the adsorption of the PGEs on the resin, Solutions treated with HF-HNO3-HCl maintained good retention of Ir, Pt, Au (>99%), Pd (>94%) and Ru (>90%), but displayed significant loss (up to 40%) of Rh. A two-step procedure was necessary to elute the precious metals from the resin: 0.3 mol l(-1) thiourea prepared in 0.1 mol(-1) HCl removed Ru, Pd, Pt, Au, and some Rh: 12 mol l(-1) HCl eluted remaining Rh and all Ir. Recoveries ranged from 50 to 100%. At low levels, the determination of PGE and Au in the thiourea fraction by ICP-MS was compromised by high levels of total dissolved solids (TDS), which necessitated dilution of the eluate prior to analysis. The TDS was reduced by decomposing thiourea with HNO3 and removing SO42- by precipitation of BaSO4, but this led to lower and more erratic results, and increased contamination. An assessment of the optimised procedure employing geological reference materials PTM-1, PTC-1 and SARM7, indicated that acceptable results should be attainable for ICP-MS determination of most elements in geological samples containing high concentrations (>1 mu g g(-1)) of the PGE, for which decomposition of thiourea is unneccessary. The addition of a decomposition step led to low recovery of all elements except Ir, which was present entirely in the HCl eluate, The method is viable for the determination of Ir in a range of geological materials, but modifications will be required if it is to be extended to the other precious metals.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 32 条
[1]  
ALIBAZI SJ, 1984, TALANTA, V31, P815
[2]  
BOUMANS PWJ, 1984, LINE COINCIDENCE TAB, V1
[3]  
BOUMANS PWJ, 1984, LINE COINCIDENCE TAB, V2
[4]   RAPID SCREENING METHOD FOR THE DETERMINATION OF PLATINUM AND PALLADIUM IN GEOLOGICAL-MATERIALS BY BATCH ION-EXCHANGE CHROMATOGRAPHY AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BRANCH, CH ;
HUTCHISON, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (06) :433-436
[5]  
BUSCH DD, ANAL CHEM, V31, P884
[6]   DECOMPOSITION TECHNIQUES [J].
CHAO, TT ;
SANZOLONE, RF .
JOURNAL OF GEOCHEMICAL EXPLORATION, 1992, 44 (1-3) :65-106
[7]   POSTDEPOSITIONAL MOBILITY OF PLATINUM, IRIDIUM AND RHENIUM IN MARINE-SEDIMENTS [J].
COLODNER, DC ;
BOYLE, EA ;
EDMOND, JM ;
THOMSON, J .
NATURE, 1992, 358 (6385) :402-404
[8]  
DELAETER JR, 1978, GEOSTANDARD NEWSLETT, V2, P9
[9]   DETERMINATION OF PLATINUM, PALLADIUM, RUTHENIUM AND IRIDIUM IN GEOLOGICAL SAMPLES BY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING A SODIUM PEROXIDE FUSION AND TELLURIUM COPRECIPITATION [J].
ENZWEILER, J ;
POTTS, PJ ;
JARVIS, KE .
ANALYST, 1995, 120 (05) :1391-1396
[10]   REVIEW OF METHODS TO DETERMINE GOLD, PLATINUM AND PALLADIUM IN PRODUCTION-ORIENTED GEOCHEMICAL LABORATORIES, WITH APPLICATION OF A STATISTICAL PROCEDURE TO TEST FOR BIAS [J].
HALL, GEM ;
BONHAMCARTER, GF .
JOURNAL OF GEOCHEMICAL EXPLORATION, 1988, 30 (03) :255-286