The Doppler kinetics of microbubble echo contrast

被引:61
作者
Schwarz, KQ
Chen, X
Bezante, GP
Phillips, D
Schlief, R
机构
[1] CTR BIOMED ULTRASOUND,ROCHESTER,NY
[2] UNIV GENOA,I-16126 GENOA,ITALY
[3] SCHERING AG,DIV CLIN RES,BERLIN,GERMANY
关键词
Doppler ultrasound; ultrasound contrast; echocardiography; Levovist; SH U 508A;
D O I
10.1016/0301-5629(96)00021-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The right and left heart kinetics of a saccharide-based microbubble echo contrast agent were measured in 11 anesthetized dogs using Doppler intensity as a measure of microbubble concentration while controlling for the dose administered, weight of the subject and cardiac output, A two-phase Doppler time-intensity curve was noted in all vascular regions, A brief first pass effect (phase 1) was found to depend on the contrast dose, cardiac output and subject size, This was followed by a much longer nearly steady-state elevation in the Doppler intensity compared with baseline (phase 2), The kinetics of phase 2 were found to be the same in all vascular distributions and independent of cardiac output. The phase 2 kinetics depend on the contrast dose, subject size and elimination characteristics of the contrast agent, The clinically important conclusions are: (1) the magnitude of Doppler enhancement and duration of the contrast effect can be predicted using the simple formulas presented; (2) the flow-dependent portion of the arterial contrast effect is effectively over only a few seconds after intravenous injection; and (3) the kinetics of phase 2 are the same throughout the body.
引用
收藏
页码:453 / 462
页数:10
相关论文
共 20 条
[1]   CHARACTERISTICS OF ALBUNEX - AIR-FILLED ALBUMIN MICROSPHERES FOR ECHOCARDIOGRAPHY CONTRAST ENHANCEMENT [J].
BARNHART, J ;
LEVENE, H ;
VILLAPANDO, E ;
MANIQUIS, J ;
FERNANDEZ, J ;
RICE, S ;
JABLONSKI, E ;
GJOEN, T ;
TOLLESHAUG, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S162-S164
[2]   OPACIFICATION AND BORDER DELINEATION IMPROVEMENT IN PATIENTS WITH SUBOPTIMAL ENDOCARDIAL BORDER DEFINITION IN ROUTINE ECHOCARDIOGRAPHY - RESULTS OF THE PHASE-III ALBUNEX MULTICENTER TRIAL [J].
CROUSE, LJ ;
CHEIRIF, J ;
HANLY, DE ;
KISSLO, JA ;
LABOVITZ, AJ ;
RAICHLEN, JS ;
SCHUTZ, RW ;
SHAH, PM ;
SMITH, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1494-1500
[3]  
DEJONG N, 1993, ULTRASOUND MED BIOL, V19, P279, DOI 10.1016/0301-5629(93)90100-3
[4]   ULTRASOUND SCATTERING PROPERTIES OF ALBUNEX MICROSPHERES [J].
DEJONG, N ;
HOFF, L .
ULTRASONICS, 1993, 31 (03) :175-181
[5]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[6]  
Galanti G, 1993, J Am Soc Echocardiogr, V6, P272
[7]   DOPPLER QUANTIFICATION OF ECHO-CONTRAST INJECTIONS INVIVO [J].
HARTLEY, CJ ;
CHEIRIF, J ;
COLLIER, KR ;
BRAVENEC, JS ;
MICKELSON, JK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (04) :269-278
[8]   Studies on the circulation I. Injection method: Physical and mathematical considerations [J].
Kinsman, JM ;
Moore, JW ;
Hamilton, WF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1929, 89 (02) :322-330
[9]   RELIABILITY OF ECHOCARDIOGRAPHIC MEASUREMENTS OF MYOCARDIAL PERFUSION USING COMMERCIALLY PRODUCED SONICATED SERUM-ALBUMIN (ALBUNEX) [J].
KLEIN, AL ;
BAILEY, AS ;
MOURA, A ;
MURRAY, RD ;
MOREHEAD, AJ ;
BRUM, J ;
PEARCE, G ;
STEWART, WJ ;
THOMAS, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1983-1993
[10]   Cardiac output determinations; Comparison of the injection method with the direct Fick procedures [J].
Moore, JW ;
Kinsman, JM ;
Hamilton, WF ;
Spurling, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1929, 89 (02) :331-339