Characterization of microporous membranes for use in membrane contactors

被引:228
作者
Iversen, SB
Bhatia, VK
DamJohansen, K
Jonsson, G
机构
[1] FLS MILJO AS, DK-2500 VALBY, DENMARK
[2] TECH UNIV DENMARK, DEPT CHEM ENGN, DK-2800 LYNGBY, DENMARK
关键词
membrane contactor; diffusion; gas and vapor permeation; microporous and porous membranes;
D O I
10.1016/S0376-7388(97)00026-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Methods of selecting applicable membranes for use in membrane contactors for flue gas desulfurization are proposed in this paper. The mass transfer mechanism for SO2 diffusion through gas filled pores is explored by simple measurements in order to identify suitable membrane structures for use in contactors for flue gas cleaning. It is attempted to correlate the experimentally determined membrane mass transfer coefficient to intrinsic physical properties of the membrane by applying theoretical and empirical correlations for the porosity-tortuosity relationship of the porous structure. Thereby limiting fluxes can be predicted with good accuracy from data quoted in the manufactures catalogue.
引用
收藏
页码:205 / 217
页数:13
相关论文
共 13 条
[1]  
CARBERRY JJ, 1987, CHEM REACTION ENG
[2]  
CUSSLER EL, 1994, NATO ADV SCI INST SE, V272, P375
[3]  
IVERSEN SB, 1994, THESIS TU DENMARK
[5]  
Kohav T.E., 1991, CHEM ENG SCI, V46, P2787
[6]   THE DIFFUSION OF ELECTROLYTES IN A CATION-EXCHANGE RESIN MEMBRANE .1. THEORETICAL [J].
MACKIE, JS ;
MEARES, P .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1955, 232 (1191) :498-509
[7]  
MASON EA, 1983, GAS TRANSFER POROUS
[8]  
MEULEN T, 1991, Patent No. 1
[9]  
OGUNDIRAN S, 1989, P PITTSB COAL C, P431
[10]   FURTHER-STUDIES ON SOLVENT-EXTRACTION WITH IMMOBILIZED INTERFACES IN A MICROPOROUS HYDROPHOBIC MEMBRANE [J].
PRASAD, R ;
KIANI, A ;
BHAVE, RR ;
SIRKAR, KK .
JOURNAL OF MEMBRANE SCIENCE, 1986, 26 (01) :79-97