Fast separations at elevated temperatures on polybutadiene-coated zirconia reversed-phase material

被引:99
作者
Li, JW [1 ]
Hu, Y [1 ]
Carr, PW [1 ]
机构
[1] UNIV MINNESOTA,DEPT CHEM,MINNEAPOLIS,MN 55455
关键词
D O I
10.1021/ac9705069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the results of thermal stability studies of polybutadiene-coated zirconia reversed phases and application tio fast HPLC separations at elevated temperatures and high flow rates. The thermal stability of the material was evaluated at temperatures up to 200 degrees C, and the rapid analyses of polyaromatic hydrocarbons and typical reversed-phase test mixtures were carried out at 100 degrees C and a flow rate of 5 mL/min. We found that the material is completely stable at 200 degrees C for at least 1300 column volumes. Analysis time can be decreased about 18-fold at high temperatures and flow rates without any significant loss in resolution relative to that at conventional temperatures and normal flow rates. For the separation of a five-component reversed-phase test mixture, the analysis time as only 50 s.
引用
收藏
页码:3884 / 3888
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 1993, ANAL METHODS INSTRUM
[2]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[3]   TEMPERATURE AS A VARIABLE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS OF PEPTIDE AND PROTEIN SAMPLES .2. SELECTIVITY EFFECTS OBSERVED IN THE SEPARATION OF SEVERAL PEPTIDE AND PROTEIN MIXTURES [J].
CHLOUPEK, RC ;
HANCOCK, WS ;
MARCHYLO, BA ;
KIRKLAND, JJ ;
BOYES, BE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY A, 1994, 686 (01) :45-59
[4]  
Dolan JW, 1997, LC GC-MAG SEP SCI, V15, P328
[5]   TEMPERATURE AS A VARIABLE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS OF PEPTIDE AND PROTEIN SAMPLES .1. OPTIMIZING THE SEPARATION OF A GROWTH-HORMONE TRYPTIC DIGEST [J].
HANCOCK, WS ;
CHLOUPEK, RC ;
KIRKLAND, JJ ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY A, 1994, 686 (01) :31-43
[6]   RAPID PEPTIDE-MAPPING BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KALGHATGI, K ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :343-354
[7]  
KEUKELEM LV, 1994, MAR ECOL-PROG SER, V114, P303
[8]   A study of the efficiency of polybutadiene-coated zirconia as a reversed-phase chromatographic support [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2193-2201
[9]   Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :837-843
[10]   Evaluation of temperature effects on selectivity in RPLC separations using polybutadiene-coated zirconia [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2202-2206