Characteristics of scattered electron beams shaped with a multileaf collimator

被引:20
作者
Moran, JM [1 ]
Martel, MK [1 ]
Bruinvis, IAD [1 ]
Fraass, BA [1 ]
机构
[1] NETHERLANDS CANC INST,DEPT RADIOTHERAPY,NL-1066 CX AMSTERDAM,NETHERLANDS
关键词
racetrack microtron; electron beams; radiation therapy; multileaf collimator; penumbra width;
D O I
10.1118/1.598046
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Characteristics of dual-foil scattered electron beams shaped with a multileaf collimator (MLC) (instead of an applicator system) were studied. The electron beams, with energies between 10 and 25 MeV, were produced by a racetrack microtron using a dual-foil scattering system. For a range of field sizes, depth dose curves, profiles, penumbra width, angular spread in air, and effective and virtual source positions were compared. Measurements were made when the MLC alone provided collimation and when an applicator provided collimation. Identical penumbra widths were obtained at a source-to-surface distance of 85 cm for the MLC and 110 cm for the applicator. The MLC-shaped beams had characteristics similar to other machines which use trimmers or applicators to collimate scanned or scattered electron beams. Values of the effective source position and the angular spread parameter for the MLC beams were similar to those of the dual-foil scattered beams of the Varian Clinac 2100CD and the scanned beams of the Sagittaire linear accelerators. A model, based on Fermi-Eyges multiple scattering theory, was adapted and applied successfully to predict penumbra width as a function of collimator-surface distance. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1491 / 1498
页数:8
相关论文
共 33 条
[1]   COMPARISON OF THE PENUMBRA BETWEEN FOCUSED AND NONDIVERGENT BLOCKS - IMPLICATIONS FOR MULTILEAF COLLIMATORS [J].
BIGGS, P ;
CAPALUCCI, J ;
RUSSELL, M .
MEDICAL PHYSICS, 1991, 18 (04) :753-758
[2]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[3]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[4]   ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON [J].
BRAHME, A ;
KRAEPELIEN, T ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04) :305-319
[5]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[6]  
Brahme A, 1983, Acta Radiol Suppl, V364, P11
[7]   CALCULATION OF ELECTRON-BEAM DEPTH-DOSE CURVES AND OUTPUT FACTORS FOR ARBITRARY FIELD SHAPES [J].
BRUINVIS, IAD ;
MATHOL, WAF .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :395-404
[8]   CALCULATION OF ELECTRON-BEAM DOSE DISTRIBUTIONS FOR ARBITRARILY SHAPED FIELDS [J].
BRUINVIS, IAD ;
VANAMSTEL, A ;
ELEVELT, AJ ;
VANDERLAARSE, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (06) :667-683
[9]   EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM [J].
GALVIN, JM ;
SMITH, AR ;
MOELLER, RD ;
GOODMAN, RL ;
POWLIS, WD ;
RUBENSTEIN, J ;
SOLIN, LJ ;
MICHAEL, B ;
NEEDHAM, M ;
HUNTZINGER, CJ ;
KLIGERMAN, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04) :789-801
[10]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192