摘要
A colorimetric flow injection-system for the determination of Cu(II) in waters based on complexation reaction with 4-(2-pyridylazo)-resorcinol, usually termed PAR, is described. Performing measurements in 0.25 mol l(-1) HNO3 medium allowed improved selectivity of the analytical method. The lack of sensitivity deriving from the low complex absorption under acidic conditions was balanced by the insertion of an immobilised poly(ethylenimine) (PEI) column where Cu(II) pre-concentration in neutral media occurs. Using sample volumes ranging from 2 to 4 ml, sampling rates of 24 and 12 samples h(-1) within a detection limit of 25 and 13 mu g l(-1), respectively, were accomplished. Accuracy of the developed methodology was assessed by comparison with atomic absorption spectrometry being the relationship [FIA] mg l(-1) = 1.00 (+/- 0.03) x [AAS] mg l(-1) + 0.00 (+/- 0.02) obtained after analysing 15 samples. Precision was also evaluated using two samples of 0.05 and 0.5 mg l(-1) copper, and a relative standard deviation (R.S.D.) better than 3% was attained for both. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 15 条
[1]   High-performance liquid chromatographic determination of trace amounts of transition metals in parenteral solutions [J].
Almeida, AA ;
Jun, X ;
Lima, JLFC .
ANALYST, 1998, 123 (06) :1283-1287
[2]   HETEROCYCLIC AZO DYESTUFFS IN ANALYTICAL CHEMISTRY - A REVIEW [J].
ANDERSON, RG ;
NICKLESS, G .
ANALYST, 1967, 92 (1093) :207-&
[3]  
[Anonymous], 1995, Standard methods for the examination of water and wastewater, V19th
[4]   A FULLY AUTOMATED FLOW-INJECTION ATOMIC-ABSORPTION SYSTEM FOR THE DETERMINATION OF COPPER TRACES IN WATERS WITH ON LINE PRECONCENTRATION IN AN ION-EXCHANGE COLUMN [J].
BURGUERA, JL ;
BURGUERA, M ;
CARRERO, P ;
MARCANO, J ;
RIVAS, C ;
BRUNETTE, MR .
JOURNAL OF AUTOMATIC CHEMISTRY, 1995, 17 (01) :25-29
[5]  
Fang Z., 1993, FLOW INJECTION SEPAR
[6]   PREPARATION AND APPLICATION OF WATER-SOLUBLE POLYMER-METAL COMPLEXES [J].
GECKELER, K ;
LANGE, G ;
EBERHARDT, H ;
BAYER, E .
PURE AND APPLIED CHEMISTRY, 1980, 52 (07) :1883-1905
[7]   DETERMINATION OF TRACE-ELEMENTS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY AFTER PRECONCENTRATION BY LIQUID-PHASE POLYMER-BASED RETENTION (LPR) [J].
GECKELER, KE ;
BAYER, E ;
SHKINEV, VM ;
SPIVAKOV, BY .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07) :763-764
[8]  
GUO ZX, 1997, FENXI KEXUE XUEBAO, V13, P228
[9]  
Helfferich F.G., 1962, Ion Exchange
[10]  
KANG SW, 1992, ANAL CHIM ACTA, V261, P197, DOI 10.1016/0003-2670(92)80191-9