3-D CFD analysis of relative humidity distribution in greenhouse with a fog cooling system and refrigerative dehumidifiers

被引:120
作者
Kim, Keesung [1 ]
Yoon, Jeong-Yeol [1 ]
Kwon, Hyuck-Jin [2 ]
Han, Jin-Hee [1 ]
Son, Jung Eek [3 ]
Nam, Sang-Woon [4 ]
Giacomelli, Gene A. [1 ]
Lee, In-Bok [2 ]
机构
[1] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
[2] Seoul Natl Univ, Dept Rural Syst Engn, Seoul 151742, South Korea
[3] Seoul Natl Univ, Dept Plant Sci, Seoul 151742, South Korea
[4] Chungnam Natl Univ, Dept Bioresources Engn, Taejon 305764, South Korea
关键词
D O I
10.1016/j.biosystemseng.2008.03.006
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The distribution of humidity in a greenhouse was studied using three-dimensional (3-D) computational fluid dynamics (CFD). The calculations were validated using experimental data from a single-span greenhouse without plants. Two types of humidity distribution were considered: humidifying using a fog cooling system, and dehumidifying using refrigerative dehumidifiers in addition to a fog cooling system. The simulation errors of RH were 0.1-18.4% with a fog cooling system and 1.1-13.1% with a fog cooling system and refrigerative dehumidifiers at each observation point. Contour maps were obtained from the 3-D CFD simulations to locate any non-uniformity in humidity distribution. The use of refrigerative dehumidifiers reduced the overall difference of humidity between the middle and bottom zones of a greenhouse, but the local distribution of humidity was uneven, especially close to the dehumidifiers. This study suggests that the developed 3-D CFD model can be a useful tool in designing and evaluating greenhouses with various configurations. (c) 2008 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:245 / 255
页数:11
相关论文
共 22 条
[1]  
ALBRIGHT L.D., 1990, ENV CONTROL ANIMALS
[2]   Combination of forced ventilation and fogging systems for cooling greenhouses [J].
Arbel, A ;
Barak, M ;
Shklyar, A .
BIOSYSTEMS ENGINEERING, 2003, 84 (01) :45-55
[3]  
Bakker JC.BotCPA, 1995, GREENHOUSE CLIMATE C, P92
[4]  
BENNET C, 1995, MOMENTUM HEAT MASS T
[5]   Convective and ventilation transfers in greenhouses, part 2: Determination of the distributed greenhouse climate [J].
Boulard, T ;
Kittas, C ;
Roy, JC ;
Wang, S .
BIOSYSTEMS ENGINEERING, 2002, 83 (02) :129-147
[6]  
BOULARD T, 1989, J AGR ENG RES, V44, P191, DOI 10.1016/S0021-8634(89)80043-5
[7]   Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics [J].
Campen, JB ;
Bot, GPA .
BIOSYSTEMS ENGINEERING, 2003, 84 (01) :69-77
[8]   Design of a low-energy dehumidifying system for greenhouses [J].
Campen, JB ;
Bot, GPA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2001, 78 (01) :65-73
[9]  
Chasseriaux G., 1987, Plasticulture, P29
[10]  
De Zwart H. F., 1996, THESIS WAGENINGEN AG THESIS WAGENINGEN AG