Parametric study of a fiber-optic laser-induced breakdown spectroscopy probe for analysis of aluminum alloys

被引:83
作者
Rai, AK
Zhang, HS
Yueh, FY
Singh, JP
Weisburg, A
机构
[1] Mississippi State Univ, Diagnost Instrumentat & Anal Lab, Starkville, MS 39762 USA
[2] Govind Ballabh Pant Univ Agr & Technol, Dept Phys, Pantnagar 263145, Uttar Pradesh, India
[3] Energy Res Co, Staten Isl, NY 10302 USA
关键词
aluminum alloys; laser-induced breakdown spectroscopy; fiber optic; calibration;
D O I
10.1016/S0584-8547(01)00299-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present work we demonstrate a fiber-optic laser-induced breakdown spectroscopy (FO LIBS) system for delivering laser energy to a sample surface to produce a spark as well as to collect the resulting radiation from the laser-induced spark. In order to improve the signal/background (S/B) ratio, various experimental parameters, such as laser energy, gate delay and width, detector gain, lenses of different focal lengths and sample surface, were tested. In order to provide high reliability and repeatability in the analysis, we also measured plasma parameters, such as electron density and plasma temperature, and determined their influence on the measurement results. The performance of FO LIBS was also compared with that of a LIBS system that does not use a fiber to transmit the laser beam. LIBS spectra with a good S/B were recorded at 2-mus gate delay and width. LIBS spectra of six different Al alloy samples were recorded to obtain calibration data. We were able to obtain linear calibration data for numerous elements (Cr, Zn, Fe, Ni, Mn, Mg and Cu). A linear calibration curve for LIBS intensity ratio vs. concentration ratio reduces the effect of physical variables (i.e. shot-to-shot power fluctuation, sample-to-surface distance, and physical properties of the samples). Our results reveal that this system may be useful in designing a high-temperature LIBS probe for measuring the elemental composition of Al melt. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:2371 / 2383
页数:13
相关论文
共 18 条
[1]   Preliminary studies of the characteristics and factors influencing the emission from a copper vapor laser-induced plasma [J].
Aucèlio, RQ ;
Castle, BC ;
Smith, BW ;
Winefordner, JD .
APPLIED SPECTROSCOPY, 2000, 54 (06) :832-837
[2]  
BARBINI R, 1997, APPL PHYS B, V65, P1101
[3]   SPECTROCHEMICAL ANALYSIS OF LIQUIDS USING THE LASER SPARK [J].
CREMERS, DA ;
RADZIEMSKI, LJ ;
LOREE, TR .
APPLIED SPECTROSCOPY, 1984, 38 (05) :721-729
[4]   REMOTE ELEMENTAL ANALYSIS BY LASER-INDUCED BREAKDOWN SPECTROSCOPY USING A FIBEROPTIC CABLE [J].
CREMERS, DA ;
BAREFIELD, JE ;
KOSKELO, AC .
APPLIED SPECTROSCOPY, 1995, 49 (06) :857-860
[5]  
Griem HR., 1964, Plasma Spectroscopy
[6]   Quantitative analysis of aluminum impurities in zinc alloy by laser-induced breakdown spectroscopy [J].
Kim, DE ;
Yoo, KJ ;
Park, HK ;
Oh, KJ ;
Kim, DW .
APPLIED SPECTROSCOPY, 1997, 51 (01) :22-29
[7]   SPECTROSCOPIC APPLICATIONS OF LASER-INDUCED PLASMAS [J].
MAJIDI, V ;
JOSEPH, MR .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) :143-162
[8]   Novel probe for laser-induced breakdown spectroscopy and Raman measurements using an imaging optical fiber [J].
Marquardt, BJ ;
Stratis, DN ;
Cremers, DA ;
Angel, SM .
APPLIED SPECTROSCOPY, 1998, 52 (09) :1148-1153
[9]   Effect of sampling geometry on elemental emissions in laser-induced breakdown spectroscopy [J].
Multari, RA ;
Foster, LE ;
Cremers, DA ;
Ferris, MJ .
APPLIED SPECTROSCOPY, 1996, 50 (12) :1483-1499
[10]   Laser-induced plasma spectroscopy (LIPS): a versatile tool for monitoring heavy metal aerosols [J].
Neuhauser, RE ;
Panne, U ;
Niessner, R .
ANALYTICA CHIMICA ACTA, 1999, 392 (01) :47-54