Periprosthetic Tissue Metal Content but Not Serum Metal Content Predicts the Type of Tissue Response in Failed Small-Diameter Metal-on-Metal Total Hip Arthroplasties

被引:63
作者
Lohmann, C. H. [1 ]
Meyer, H. [1 ]
Nuechtern, J. V. [1 ]
Singh, G. [1 ]
Junk-Jantsch, S. [1 ]
Schmotzer, H. [1 ]
Morlock, M. M. [1 ]
Pflueger, G. [1 ]
机构
[1] Otto Von Guericke Univ, Dept Orthopaed Surg, D-39120 Magdeburg, Germany
关键词
RETRIEVAL ANALYSIS; ADVERSE-REACTION; REPLACEMENT; BEARINGS; COBALT; WEAR; HYPERSENSITIVITY; COMPLEXES; RELEASE; DEBRIS;
D O I
10.2106/JBJS.L.01273
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Tissue responses to periprosthetic metal wear debris are complex and poorly understood. There are two predominant tissue responses: a nonspecific macrophage-mediated granulomatous response and lymphocyte-dominated response, which has immunological memory and is mediated by T cells. Delayed hypersensitivity-type responses may accelerate aseptic loosening of arthroplasty implants. We hypothesized that the metal content of periprosthetic tissue but not of serum would be predictive of the type of tissue response to metal wear debris. Methods: We examined twenty-eight total hip arthroplasty implant retrievals from twenty-seven patients who had undergone revision arthroplasty at one institution. Indications for revision were pain and/or osteolysis; one patient had recurrent dislocations. Tissue samples were analyzed microscopically and the metal (Co, Cr, and Ni) content was determined. Explanted prosthetic components were examined for linear wear. Intraoperatively, periprosthetic metallosis was observed in twelve cases and formation of a bursa (pseudotumor) was observed in thirteen. The acetabular cup was loose in eleven cases, the femoral stem was loose in five, and both components were loose in five. Results: The metal (Co, Cr, and Ni) content of the periprosthetic tissue ranged from 1.4 to 4604.0 mu g/g. Histologically, macrophages containing metal particles as well as diffuse and perivascular lymphocytic infiltration were observed. Fibrin exudation was also visible. Tissues that displayed a predominantly lymphocytic response had a mean metal content of 222.2 +/- 52.9 mu g/g, whereas those that displayed a macrophage-dominated response had a metal content of 3.0 +/- 0.9 mu g/g; this difference was significant (p = 0.001). The mean serum metal content did not differ significantly between the two subgroups (60.7 +/- 13.4 compared with 43.7 +/- 3.8 mu g/L, p = 0.105). Conclusions: An association between periprosthetic tissue metal content and hypersensitivity appears likely but needs to be validated with larger-scale retrieval studies.
引用
收藏
页码:1561 / 1568
页数:8
相关论文
共 24 条
[1]
Immunologic Adverse Reaction Associated with Low-carbide Metal-on-metal Bearings in Total Hip Arthroplasty [J].
Aroukatos, Panagiotis ;
Repanti, Maria ;
Repantis, Thomas ;
Bravou, Vassiliki ;
Korovessis, Panagiotis .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (08) :2135-2142
[2]
Large-Diameter Modular Metal-on-Metal Total Hip Arthroplasty Incidence of Revision for Adverse Reaction to Metallic Debris [J].
Barrett, William P. ;
Kindsfater, Kirk A. ;
Lesko, James P. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :976-983
[3]
Barrett WP, 2012, J ARTHROPLASTY, V27, pe1
[4]
Pseudotumors Associated with Total Hip Arthroplasty [J].
Daniel, Joseph ;
Holland, James ;
Quigley, Laura ;
Sprague, Sheila ;
Bhandari, Mohit .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (01) :86-93
[5]
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement [J].
De Haan, R. ;
Pattyn, C. ;
Gill, H. S. ;
Murray, D. W. ;
Campbell, P. A. ;
De Smet, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1291-1297
[6]
Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern [J].
Delaunay, C. ;
Petit, I. ;
Learmonth, I. D. ;
Oger, P. ;
Vendittoli, P. A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) :894-904
[7]
Wear particles, periprosthetic osteolysis and the immune system [J].
Goodman, Stuart B. .
BIOMATERIALS, 2007, 28 (34) :5044-5048
[8]
Lymphocyte responses in patients with total hip arthroplasty [J].
Hallab, NJ ;
Anderson, S ;
Stafford, T ;
Glant, T ;
Jacobs, JJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (02) :384-391
[9]
Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation [J].
Hallab, NJ ;
Mikecz, K ;
Vermes, C ;
Skipor, A ;
Jacobs, JJ .
MOLECULAR AND CELLULAR BIOCHEMISTRY, 2001, 222 (1-2) :127-136
[10]
Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37