Last stage control and mechanical transfer function measurement of the VIRGO suspensions

被引:13
作者
Bozzi, A
Bourgoin, C
Cortese, S
Errico, A
Enard, D
Mataguez, S
Paoli, A
Pasqualetti, A
Popolizio, P
Richard, F
Teuler, JM
Zhang, Z
Boccara, C
Leliboux, M
Loriette, V
Reita, V
Roger, JP
Ganau, P
Lagrange, B
Mackowski, JM
Michel, C
Montorio, JL
Morgado, N
Pinard, L
Remillieux, A
Bracci, L
Calamai, G
Cuoco, E
Dominici, P
Fabbroni, L
Guidi, G
Losurdo, G
Martelli, F
Mazzoni, M
Ripepe, M
Stanga, R
Vetrano, F
Acernese, F
Barone, F
Calloni, E
Cavaliere, S
De Rosa, M
De Rosa, R
Di Fiore, L
Eleuteri, A
Evangelista, G
Garufi, F
Maiorino, M
Milano, L
Qipiani, K
机构
[1] Ist Nazl Fis Nucl, Sez Napoli, I-80126 Naples, Italy
[2] EGO, I-56021 S Stefano A Macerata, Pi, Italy
[3] ESPCI, F-75005 Paris, France
[4] IPNL, F-69622 Villeurbanne, France
[5] Ist Nazl Fis Nucl, Sez Firenze, I-50125 Florence, Italy
[6] Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy
[7] Univ Salerno, Dipartimento Sci Farmaceut, I-84084 Fisciano, Sa, Italy
[8] Ist Nazl Fis Nucl, Sez Perugia, I-06123 Perugia, Italy
[9] Univ Perugia, I-06123 Perugia, Italy
[10] Ist Nazl Fis Nucl, Sez Pisa, I-56010 Pisa, Italy
[11] Ist Nazl Fis Nucl, Sez Roma 1, I-00185 Rome, Italy
[12] Lab Accelerateur Lineaire, F-91898 Orsay, France
[13] LAPP, F-74941 Annecy Le Vieux, France
[14] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Roma, Italy
[15] Observ Cote Azur, F-06034 Nice 4, France
关键词
D O I
10.1063/1.1463717
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The automatic control of the suspended mirrors is a major task in operating an interferometric gravitational wave antenna. To reach the extreme sensitivity required for this kind of detector, an accurate alignment and a stable locking of the interferometer on its working point are crucial. The solution of this problem is particularly complex in the case of a multistage pendulum, such as the suspension system for seismic isolation adopted in VIRGO. A precise knowledge of the suspension mechanical transfer functions (TFs) for different forces applied in the control servo-loops represents essential information to reach the goal. In this article, we describe the apparatus we developed to measure the VIRGO suspension TF and we report the results thus obtained on full-scale suspensions at the VIRGO site. Preliminary results for the implemented control system of the last suspension stage are also presented. (C) 2002 American Institute of Physics.
引用
收藏
页码:2143 / 2149
页数:7
相关论文
共 13 条
[1]   Measurement of the VIRGO superattenuator performance for seismic noise suppression [J].
Ballardin, G ;
Bracci, L ;
Braccini, S ;
Bradaschia, C ;
Casciano, C ;
Calamai, G ;
Cavalieri, R ;
Cecchi, R ;
Cella, G ;
Cuoco, E ;
D'Ambrosio, E ;
Dattilo, V ;
Di Virgilio, A ;
Fabbroni, L ;
Fidecaro, F ;
Frasconi, F ;
Gaddi, A ;
Gennai, A ;
Gennaro, G ;
Giazotto, A ;
Losurdo, G ;
Holloway, L ;
La Penna, P ;
Lelli, F ;
Majorana, E ;
Mazzoni, M ;
Paoletti, F ;
Pasotti, M ;
Pasqualetti, A ;
Passaquieti, R ;
Passuello, D ;
Poggiani, R ;
Puppo, P ;
Raffaelli, F ;
Rapagnani, P ;
Ricci, F ;
Ruggi, P ;
Stanga, R ;
Taddei, R ;
Vetrano, F ;
Vicerè, A ;
Zhang, Z .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (09) :3643-3652
[2]  
BARSUGLIA M, 2000, VIRNOTNAP1390143
[3]   Suspension last stages for the mirrors of the Virgo interferometric gravitational wave antenna [J].
Bernardini, A ;
Majorana, E ;
Puppo, P ;
Rapagnani, P ;
Ricci, F ;
Testi, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08) :3463-3472
[4]  
CALBUCCI V, 2001, VIRNOTNAP1390173
[5]  
CALBUCCI V, 2001, VIRNOTNAP1390174
[6]   An interferometric device to measure the mechanical transfer function of the VIRGO mirrors suspensions [J].
Calloni, E ;
Di Fiore, L ;
Grado, A ;
Milano, L .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (04) :1882-1885
[7]  
Caron B, 1997, CLASSICAL QUANT GRAV, V14, P1461, DOI 10.1088/0264-9381/14/6/011
[8]   A preliminary study of the locking of an interferometer for gravitational wave detection [J].
Caron, B ;
Dominjon, A ;
Drezen, C ;
Flaminio, R ;
Grave, X ;
Hermel, R ;
Marion, F ;
Massonnet, L ;
Mehmel, C ;
Morand, R ;
Mours, B ;
Sannibale, V ;
Yvert, M .
ASTROPARTICLE PHYSICS, 1997, 6 (02) :245-256
[9]  
DANZMANN K, 1995, 1 E AM C GRAV WAV EX, P23003
[10]  
FRITSCHEL P, 1997, 2 E AM C GRAV WAV