Effects of adjustment for referral bias on the sensitivity and specificity of single photon emission computed tomography for the diagnosis of coronary artery disease

被引:83
作者
Miller, TD
Hodge, DO
Christian, TF
Milavetz, JJ
Bailey, KR
Gibbons, RJ
机构
[1] Mayo Clin & Mayo Fdn, Dept Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Cardiovasc Dis, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Hlth Sci Res, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0002-9343(01)01111-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: Referral bias, in which the result of a diagnostic test affects the subsequent referral for a more definitive test, influences the accuracy of noninvasive tests for coronary artery disease. This study evaluates the effect of referral bias on the apparent accuracy of single photon emission computed tomography (SPECT). SUBJECTS AND METHODS: Over a 10-year period, 14 273 patients without known coronary artery disease underwent stress SPECT, Coronary angiography was performed within 3 months after the stress test in 1853 patients (13%). The apparent sensitivity, specificity, and likelihood ratios of SPECT were determined in these patients, and then adjusted for referral bias using two different formulas. RESULTS: The overwhelming majority (95%) of patients who under-went angiography had abnormal SPECT images. Apparent values for test indices were a sensitivity of 98%, a specificity of 13%, a likelihood ratio for a positive test of 1.1, and a likelihood ratio for a negative test of 0.15. Test indices adjusted for referral bias (using the two methods) were a sensitivity of 65% or 67%, a specificity of 67% or 75%, a likelihood ratio for a positive test of 2.0 or 2.7, and a likelihood ratio for a negative test of 0.44 or 0.52. CONCLUSION: Referral bias has a marked effect on the apparent accuracy of stress SPECT for the diagnosis of coronary disease. Adjustment for referral bias yields estimates for sensitivity and specifity and likelihood ratios that better reflect the accuracy of the technique. (C)2002 by Excerpta Medica, Inc.
引用
收藏
页码:290 / 297
页数:8
相关论文
共 47 条
[1]   TL-201 MYOCARDIAL PERFUSION IMAGING IN AORTIC-VALVE STENOSIS [J].
BAILEY, IK ;
COME, PC ;
KELLY, DT ;
BUROW, RD ;
GRIFFITH, LSC ;
STRAUSS, HW ;
PITT, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (06) :889-899
[2]   ASSESSMENT OF DIAGNOSTIC-TESTS WHEN DISEASE VERIFICATION IS SUBJECT TO SELECTION BIAS [J].
BEGG, CB ;
GREENES, RA .
BIOMETRICS, 1983, 39 (01) :207-215
[3]   PROGNOSTIC VALUE OF TL-201 MYOCARDIAL PERFUSION IMAGING - A DIAGNOSTIC-TOOL COMES OF AGE [J].
BROWN, KA .
CIRCULATION, 1991, 83 (02) :363-381
[4]   PROGNOSIS WITH ABNORMAL THALLIUM IMAGES IN THE ABSENCE OF SIGNIFICANT CORONARY-ARTERY DISEASE [J].
CANNAN, CR ;
MILLER, TD ;
CHRISTIAN, TF ;
BAILEY, KR ;
GIBBONS, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (15) :1276-1280
[5]   The importance of work-up (verification) bias correction in assessing the accuracy of SPECT thallium-201 testing for the diagnosis of coronary artery disease [J].
Cecil, MP ;
Kosinski, AS ;
Jones, MT ;
Taylor, A ;
Alazraki, NP ;
Pettigrew, RI ;
Weintraub, WS .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1996, 49 (07) :735-742
[6]   NONINVASIVE IDENTIFICATION OF SEVERE CORONARY-ARTERY DISEASE USING EXERCISE TOMOGRAPHIC TL-201 IMAGING [J].
CHRISTIAN, TF ;
MILLER, TD ;
BAILEY, KR ;
GIBBONS, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (01) :14-20
[7]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[8]   FACTORS AFFECTING SENSITIVITY AND SPECIFICITY OF A DIAGNOSTIC-TEST - THE EXERCISE THALLIUM SCINTIGRAM [J].
DETRANO, R ;
JANOSI, A ;
LYONS, KP ;
MARCONDES, G ;
ABBASSI, N ;
FROELICHER, VF .
AMERICAN JOURNAL OF MEDICINE, 1988, 84 (04) :699-710
[9]   OFF BAYES - EFFECT OF VERIFICATION BIAS ON POSTERIOR PROBABILITIES CALCULATED USING BAYES THEOREM [J].
DIAMOND, GA .
MEDICAL DECISION MAKING, 1992, 12 (01) :22-31
[10]   HOW ACCURATE IS SPECT THALLIUM SCINTIGRAPHY [J].
DIAMOND, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :1017-1021