Microfabricated electrochemical sensor for the detection of radiation-induced DNA damage

被引:67
作者
Wang, J
Rivas, G
Ozsos, M
Grant, DH
Cai, XH
Parrado, C
机构
[1] NATL UNIV CORDOBA,DEPT QUIM FIS,RA-5016 CORDOBA,ARGENTINA
[2] EGE UNIV,FAC PHARM,TR-35100 IZMIR,TURKEY
[3] MT ALLISON UNIV,DEPT CHEM,SACKVILLE,NB E0A 3C0,CANADA
[4] UNIV COMPLUTENSE MADRID,FAC CIENCIAS QUIM,DEPT QUIM ANALIT,E-28040 MADRID,SPAIN
关键词
D O I
10.1021/ac961000d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor protocol for the detection of radiation-induced DNA damage is described, The procedure employs a dsDNA-coated screen-printed electrode and relies on changes in the guanine-DNA oxidation signal upon exposure to ultraviolet radiation, The decreased signal is ascribed primarily to conformational changes in the DNA and to the photoconversion of the guanine-DNA moiety to a nonelectroactive monomeric base product. Factors influencing the response of these microfabricated DNA sensors, such as irradiation time, wavelength, and distance, are explored, and future prospects are discussed, Similar results are given for the use of bare strip electrodes in connection with irradiated DNA solutions.
引用
收藏
页码:1457 / 1460
页数:4
相关论文
共 8 条
[1]   DETECTING DNA-DAMAGE [J].
CADET, J ;
WEINFELD, M .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :A675-A682
[2]   MONOMERIC BASE DAMAGE PRODUCTS FROM ADENINE, GUANINE, AND THYMINE INDUCED BY EXPOSURE OF DNA TO ULTRAVIOLET-RADIATION [J].
DOETSCH, PW ;
ZASTAWNY, TH ;
MARTIN, AM ;
DIZDAROGLU, M .
BIOCHEMISTRY, 1995, 34 (03) :737-742
[3]   A NEW ELECTROCHEMICAL APPROACH FOR THE INVITRO INVESTIGATION OF DAMAGE IN NATIVE DNA BY SMALL GAMMA-RADIATION DOSES [J].
SEQUARIS, JM ;
VALENTA, P ;
NURNBERG, HW .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1982, 42 (04) :407-415
[4]   STUDY OF CHANGES IN DNA CONFORMATION CAUSED BY IONIZING AND ULTRAVIOLET-RADIATION BY MEANS OF PULSE POLAROGRAPHY AND CIRCULAR-DICHROISM [J].
VORLICKOVA, M ;
PALECEK, E .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1974, 26 (04) :363-372
[5]   Microfabricated thick-film electrochemical sensor for nucleic acid determination [J].
Wang, J ;
Cai, XH ;
Tian, BM ;
Shiraishi, H .
ANALYST, 1996, 121 (07) :965-969
[6]   Adsorptive stripping potentiometry of DNA at electrochemically pretreated carbon paste electrodes [J].
Wang, J ;
Cai, XH ;
Jonsson, C ;
Balakrishnan, M .
ELECTROANALYSIS, 1996, 8 (01) :20-24
[8]   THE COMPLEXITY OF DNA-DAMAGE - RELEVANCE TO BIOLOGICAL CONSEQUENCES [J].
WARD, JF .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1994, 66 (05) :427-432