The dependence of prostate postimplant dosimetric quality on CT volume determination

被引:45
作者
Merrick, GS
Butler, WM
Dorsey, AT
Lief, JH
机构
[1] Wheeling Hosp, Schiffler Oncol Ctr, Wheeling, WV 26003 USA
[2] George Washington Univ, Med Ctr, Div Radiat Oncol & Biophys, Washington, DC 20037 USA
[3] Wheeling Jesuit Univ, Wheeling, WV USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 44卷 / 05期
关键词
prostate brachytherapy; dosimetry; CT volume; quality;
D O I
10.1016/S0360-3016(99)00137-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The postoperative evaluation of permanent prostate brachytherapy requires a subjective determination of the implant volume. This work investigates the magnitude of the effect that various methods of treatment volume delineation have on dosimetric quality parameters for a treatment planning philosophy that defines a target volume as the prostate with a periprostatic margin. Methods and Materials: Eight consecutive prostate brachytherapy patients with a prescribed dose of 145 Gy from I-125 as monotherapy comprised the study population. The prostate ultrasound volume was enlarged to a planning volume by an average factor of 1.8 to encompass probable extracapsular extension in the periprostatic region. For this cohort, the mean pretreatment parameters were 30.3 cm(3) ultrasound volume, 51.8 cm(3) planning volume, 131 seeds per patient, and 42.9 mCi total activity. On CT study sets obtained less than 2 hours postoperatively, target volumes mere drawn using three methods: prostate plus a periprostatic margin, prostate only which excluded the puborectalis muscles, the periprostatic fat and the periprostatic venous plexus, and the preplanning ultrasound magnified to conform to the magnification factor of the postimplant CT scan. Three sets of 5 dosimetric quality parameters corresponding to the different volumetric approaches were calculated: V100, V150, and V200 which are the fractions of the target volume covered by 100, 150, and 200% of the prescribed dose, and D90 and D100, which are the minimal doses covering 90 and 100 % of the target volume. Results: The postoperative CT volume utilizing the prostate plus margin technique was comparable to the initial planning volume (mean 55.5 cm3 vs. 51.8 cm3, respectively) whereas those determined via superimposing the preplan ultrasound resulted in volumes nearly identical to the initial ultrasound evaluation (mean 32.4 cm(3) vs. 30.3 cm3). The prostate only approach resulted in volumes approximately 25% larger than the ultrasound volume approach. Despite the volume determinations being markedly different, no significant differences between the approaches were appreciated for V100, V150, V200, and D90. Large variations seen in D100 were uncorrelated to any of the other parameters and make D100 unsuitable as a quality indicator. Conclusions: In terms of a logarithmic measure, the variation between volumetric approach for V100, V150, V200, and D90 was less than one-fifth the variation of the CT volumes. These results which indicate relative independence of postimplant CT volume determination and dosimetric quality are only valid for a planning philosophy that includes the prostate with a periprostatic margin as the target volume. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1111 / 1117
页数:7
相关论文
共 39 条
[1]  
[Anonymous], 1997, Prostate brachytherapy made complicated
[2]   Centralized multiinstitutional postimplant analysis for interstitial prostate brachytherapy [J].
Bice, WS ;
Prestidge, BR ;
Grimm, PD ;
Friedland, JL ;
Feygelman, V ;
Roach, M ;
Prete, JL ;
Dubois, DF ;
Blasko, JC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :921-927
[3]   PROSTATE-SPECIFIC ANTIGEN BASED DISEASE-CONTROL FOLLOWING ULTRASOUND-GUIDED (125)IODINE IMPLANTATION FOR STAGE T1/T2 PROSTATIC-CARCINOMA [J].
BLASKO, JC ;
WALLNER, K ;
GRIMM, PD ;
RAGDE, H .
JOURNAL OF UROLOGY, 1995, 154 (03) :1096-1099
[4]   Prognostic significance of prostate-specific antigen in stage T1c prostate cancer treated by radical prostatectomy [J].
Cookson, MS ;
Fleshner, NE ;
Soloway, SM ;
Fair, WR .
UROLOGY, 1997, 49 (06) :887-893
[5]   Pd-103 brachytherapy and external beam irradiation for clinically localized, high-risk prostatic carcinoma [J].
Dattoli, M ;
Wallner, K ;
Sorace, R ;
Koval, J ;
Cash, J ;
Acosta, R ;
Brown, C ;
Etheridge, J ;
Binder, M ;
Brunelle, R ;
Kirwan, N ;
Sanchez, S ;
Stein, D ;
Wasserman, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :875-879
[6]  
Dattoli MJ, 1997, INT J RADIAT ONCOL, V39, P221
[7]  
GRIMM PD, COMMUNICATION
[8]  
Merrick G S, 1998, Radiat Oncol Investig, V6, P182, DOI 10.1002/(SICI)1520-6823(1998)6:4<182::AID-ROI6>3.3.CO
[9]  
2-E
[10]  
Merrick G S, 1997, Radiat Oncol Investig, V5, P305, DOI 10.1002/(SICI)1520-6823(1997)5:6<305::AID-ROI7>3.0.CO