Optimization of elution salt concentration in stepwise elution of protein chromatography using linear gradient elution data - Reducing residual protein A by cation-exchange chromatography in monoclonal antibody purification

被引:23
作者
Ishihara, T [1 ]
Kadoya, T
Endo, N
Yamamoto, S
机构
[1] Kirin Brewery Co Ltd, Div Pharmaceut, CMC R&D Labs, Takasaki, Gumma 3700013, Japan
[2] Yamaguchi Univ, Dept Chem Engn, Ube, Yamaguchi 7558611, Japan
关键词
antibody; preparative chromatography; stepwise elution; chromatography models; gradient elution;
D O I
10.1016/j.chroma.2006.02.042
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Our simple method for optimization of the elution salt concentration in stepwise elution was applied to the actual protein separation system, which involves several difficulties such as detection of the target. As a model separation system, reducing residual protein A by cation-exchange chromatography in human monoclonal antibody (hMab) purification was chosen. We carried out linear gradient elution experiments and obtained the data for the peak salt concentration of hMab and residual protein A, respectively. An enzyme-linked immunosorbent assay was applied to the measurement of the residual protein A. From these data, we calculated the distribution coefficient of the hMab and the residual protein A as a function of salt concentration. The optimal salt concentration of stepwise elution to reduce the residual protein A from the hMab was determined based on the relationship between the distribution coefficient and the salt concentration. Using the optimized condition, we successfully performed the separation, resulting in high recovery of hMab and the elimination of residual protein A. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 21 条
[1]
DETECTION AND REDUCTION OF PROTEIN-A CONTAMINATION IN IMMOBILIZED PROTEIN-A PURIFIED MONOCLONAL-ANTIBODY PREPARATIONS [J].
BLOOM, JW ;
WONG, MF ;
MITRA, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 117 (01) :83-89
[2]
SEPARATION OF NEUTRAL PROTEINS ON ION-EXCHANGE RESINS [J].
BOARDMAN, NK ;
PARTRIDGE, SM .
BIOCHEMICAL JOURNAL, 1955, 59 (04) :543-552
[3]
Identification of protein A media performance attributes that can be monitored as surrogates for retrovirus clearance during extended re-use [J].
Brorson, K ;
Brown, J ;
Hamilton, E ;
Stein, KE .
JOURNAL OF CHROMATOGRAPHY A, 2003, 989 (01) :155-163
[4]
Fahrner R L, 2001, Biotechnol Genet Eng Rev, V18, P301
[5]
Detection and purification of two antibody-antigen complexes via selective adsorption on lowly activated anion exchangers [J].
Fuentes, M ;
Pessela, FBCC ;
Mateo, C ;
Munilla, R ;
Guisán, JM ;
Fernandez-Lafuente, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1059 (1-2) :89-94
[6]
Gagnon P., 1996, Purification tools for monoclonal antibodies
[7]
Optimization of preparative ion-exchange chromatography of proteins: Linear gradient separations [J].
Gallant, SR ;
Vunnum, S ;
Cramer, SM .
JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (02) :295-314
[8]
Guiochon G., 1994, FUNDAMENTALS PREPARA
[9]
Optimization of monoclonal antibody purification by ion-exchange chromatography - Application of simple methods with linear gradient elution experimental data [J].
Ishihara, T ;
Yamamoto, S .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1069 (01) :99-106
[10]
KARLSSON E, 1998, PROTEIN PURIFICATION