Fluorinated diamond-like carbon as antithrombogenic coating for blood-contacting devices

被引:79
作者
Hasebe, T
Shimada, A
Suzuki, T
Matsuoka, Y
Saito, T
Yohena, S
Kamijo, A
Shiraga, N
Higuchi, M
Kimura, K
Yoshimura, H
Kuribayashi, S
机构
[1] Tachikawa Hosp, Dept Radiol, Tokyo 1908531, Japan
[2] Kitasato Univ, Sch Med, Dept Thorac Cardiovasc Surg, Sagamihara, Kanagawa 2288555, Japan
[3] Keio Univ, Sch Sci & Technol, Dept Mech Engn, Ctr Mat Sci,Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[4] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo 1608582, Japan
关键词
fluorinated diamond-like carbon film; hemocompatibility; biocompatibility; hydrophobicity; thrombogenicity;
D O I
10.1002/jbm.a.30512
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diamond-like carbon (DLC) is being considered for widespread clinical use as a surface coating for cardiovascular devices. We synthesized fluorinated DLC (F-DLC) coatings in order to create a more hydrophobic surface with improved antithrombogenicity and flexibility when compared with conventional DLC coatings by combining the inertness of DLC films with the advantage of fluorination. The purpose of this study was to evaluate the in vitro hemocompatibility and in vivo biocompatibility of the F-DLC coating for medical devices. The in vitro whole blood model confirmed that platelet loss was lower in the F-DLC group than in the noncoated group (SUS316L), which suggests the adhesion of a smaller number of platelets to F-DLC-coated materials. Furthermore, the biomarkers of mechanically induced platelet activation (beta-thromboglobulin) and activated coagulation (thrombin-antithrombin-three complex) were markedly reduced in the F-DLC-coated group. In vivo rat implant model studies revealed no excessive local and systemic inflammatory responses in the F-DLC group. The thickness of the fibrous tissue capsule surrounding the F-DLC-coated disk was almost equal to that of the noncoated SUS316L disk, which has the favorable biocompatibility for metallic implant materials. F-DLC coating thus appears to be a promising candidate for use as a coating material in blood-contacting devices. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 31 条
[1]  
Affatato S, 2000, J BIOMED MATER RES, V53, P221, DOI 10.1002/(SICI)1097-4636(2000)53:3<221::AID-JBM6>3.0.CO
[2]  
2-Z
[3]   Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease [J].
Airoldi, F ;
Colombo, A ;
Tavano, D ;
Stankovic, G ;
Klugmann, S ;
Paolillo, V ;
Bonizzoni, E ;
Briguori, C ;
Carlino, M ;
Montorfano, M ;
Liistro, F ;
Castelli, A ;
Ferrari, A ;
Sgura, F ;
Di Mario, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :474-477
[4]  
Allen M, 2001, J BIOMED MATER RES, V58, P319, DOI 10.1002/1097-4636(2001)58:3<319::AID-JBM1024>3.3.CO
[5]  
2-6
[6]   The effects of diamond-like carbon coatings on macrophages, fibroblasts and osteoblast-like cells in vitro [J].
Allen, M. ;
Law, F. ;
Rushton, N. .
Clinical Materials, 1994, 17 (01) :1-10
[7]  
Anderson JM, 1994, PROB GEN SURG, V11, P147
[8]  
De Scheerder I, 2000, J INVASIVE CARDIOL, V12, P389
[9]  
Dearnaley G., 1993, Clinical Materials, V12, P237, DOI 10.1016/0267-6605(93)90078-L
[10]  
Disegi J A, 2000, Injury, V31 Suppl 4, P2