Cigarette filter as sorbent for on-line coupling of solid-phase extraction to high-performance liquid chromatography for determination of polycyclic aromatic hydrocarbons in water

被引:45
作者
Liang, HD
Han, DM
Yan, XP [1 ]
机构
[1] Nankai Univ, Dept Chem, Res Ctr Analyt Sci, Key Lab Funct Polymer Mat,Minist Educ, Tianjin 300071, Peoples R China
[2] Taizhou Univ, Dept Chem, Linhai 317000, Peoples R China
基金
中国国家自然科学基金;
关键词
solid-phase extraction; cigarette filter; high-performance liquid chromatography; PAHs;
D O I
10.1016/j.chroma.2005.11.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-line solid-phase extraction (SPE) protocol using the cigarette filter as sorbent coupled with high-performance liquid chromatography (HPLC) was developed for simultaneous determination of trace naphthalene (NAPH), phenanthrene (PHEN), anthracene (ANT), fluoranthene (FLU), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), benzo(a)pyrene (BaP), and benzo(ghi)peryiene (BghiP) in water samples. To on-line interface solid-phase extraction to HPLC, a preconcentration column packed with the cigarette filter was used to replace a conventional sample loop on the injector valve of the HPLC for on-line solid-phase extraction. The sample solution was loaded and the analytes were then preconcentrated onto the preconcentration column. The collected analytes were subsequently eluted with a mobile phase of methanol-water (95:5). HPLC with a photodiode array detector was used for their separation and detection. The detection limits (S/N = 3) for preconcentrating 42 mL of sample solution ranged from 0.9 to 58.6 ng L-1 at a sample throughput of 2 samples h(-1). The enhancement factors were in the range of 409-1710. The developed method was applied to the determination of trace NAPH, PHEN, ANT, FLU, BbF, BkF, BaP and BahiP in local river water samples. The recoveries of PAHs spiked in real water samples ranged from 87 to 115%. The precisions for nine replicate measurements of a standard mixture (NAPH: 4.0 mu g L-1, PHEN: 0.40 mu g L-1 ANT: 0.40 mu g L-1, FLU: 2.0 mu g L-1, BbF: 1.6 mu g L-1, BkF: 2.0 mu g L-1, BaP: 2.0 mu g L-1, BghiP: 1.7 mu g L-1) were in the range of 1.2-5.1%. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 15 条
  • [1] A REVIEW OF ATMOSPHERIC POLYCYCLIC AROMATIC-HYDROCARBONS - SOURCES, FATE AND BEHAVIOR
    BAEK, SO
    FIELD, RA
    GOLDSTONE, ME
    KIRK, PW
    LESTER, JN
    PERRY, R
    [J]. WATER AIR AND SOIL POLLUTION, 1991, 60 (3-4) : 279 - 300
  • [2] A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS
    BERRUETA, LA
    GALLO, B
    VICENTE, F
    [J]. CHROMATOGRAPHIA, 1995, 40 (7-8) : 474 - 483
  • [3] On-line coupling of flow injection displacement sorption preconcentration to high-performance liquid chromatography for speciation analysis of mercury in seafood
    Dong, LM
    Yan, XP
    Li, Y
    Jiang, Y
    Wang, SW
    Jiang, DQ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (02) : 119 - 125
  • [4] Trends of flow injection sample pretreatment approaching the new millennium
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 1999, 400 : 233 - 247
  • [5] Detection of polycyclic aromatic hydrocarbon levels in milk collected near potential contamination sources
    Grova, N
    Feidt, C
    Crépineau, C
    Laurent, C
    Lafargue, PE
    Hachimi, A
    Rychen, G
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (16) : 4640 - 4642
  • [6] JIA RB, 1999, J ENV MONITOR CHINA, V15, P40
  • [7] LUBOV O, 2005, ANAL CHIM ACTA, V538, P35
  • [8] Polycyclic aromatic hydrocarbons in natural waters: sources, occurrence and analysis
    Manoli, E
    Samara, C
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (06) : 417 - 428
  • [9] Determination of PAH in food samples by HPLC with fluorimetric detection following sonication extraction without sample clean-up
    Nieva-Cano, MJ
    Rubio-Barroso, S
    Santos-Delgado, MJ
    [J]. ANALYST, 2001, 126 (08) : 1326 - 1331
  • [10] On-line coupling of solid-phase extraction to gas chromatography with mass spectrometric detection to determine pesticides in water
    Pocurull, E
    Aguilar, C
    Borrull, F
    Marcé, RM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 818 (01) : 85 - 93