High sensitive analysis of rat serum bile acids by liquid chromatography/electrospray ionization tandem mass spectrometry

被引:69
作者
Ando, M
Kaneko, T
Watanabe, R
Kikuchi, S
Goto, T
Iida, T
Hishinuma, T
Mano, N
Goto, J
机构
[1] Tohoku Univ, Grad Sch Pharmaceut Sci, Dept Clin Pharm, Aoba Ku, Sendai, Miyagi 9808574, Japan
[2] Niigata Univ Pharm & Appl Life Sci, Niigata 9502081, Japan
[3] Tohoku Univ, Grad Sch Pharmaceut Sci, Lab Bioanalyt Chem, Aoba Ku, Sendai, Miyagi 9808578, Japan
[4] Nihon Univ, Coll Humanities & Sci, Dept Chem, Setagaya Ku, Tokyo 1568550, Japan
[5] Tohoku Univ Hosp, Dept Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808574, Japan
关键词
bile acid; rat serum; LC-MS/MS; electrospray ionization; simultaneous determination;
D O I
10.1016/j.jpba.2005.09.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive liquid chromatography (LC)/electrospray ionization (ESI) tandem mass spectrometry (MS) can be used to analyze the bile acid composition of rat serum. This method can analyze eight common bile acids and their glycine and taurine conjugates in 100 d rodent serum by gradient elution on a reversed-phase column using a mixture of 20 mM arnmoniurn acetate buffer (pH 8.0), acetonitrile and methanol as a mobile phase. Selected reaction monitoring analysis under negative ion detection mode allowed the achievement of a high sensitive assay with a simple solid phase extraction using an ODS cartridge column. We used this method to investigate the effect of a one-day fast on the concentration and cornposition of serum bile acids in rats. The results suggested that the method described here is useful for the dynamic analysis of serum bile acids in rats. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1179 / 1186
页数:8
相关论文
共 22 条
[1]   Identification of a novel gene family encoding human liver-specific organic anion transporter LST-1 [J].
Abe, T ;
Kakyo, M ;
Tokui, T ;
Nakagomi, R ;
Nishio, T ;
Nakai, D ;
Nomura, H ;
Unno, M ;
Suzuki, M ;
Naitoh, T ;
Matsuno, S ;
Yawo, H .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (24) :17159-17163
[2]   Human bile salt export pump promoter is transactivated by the farnesoid X receptor/bile acid receptor [J].
Ananthanarayanan, M ;
Balasubramanian, N ;
Makishima, M ;
Mangelsdorf, DJ ;
Suchy, FJ .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2001, 276 (31) :28857-28865
[3]  
Danielsson H., 1973, BILE ACIDS PHYSIOLOG, V2, P1
[4]  
Falany CN, 1997, J LIPID RES, V38, P1139
[5]   STUDIES ON STEROIDS .238. DETERMINATION OF BILE-ACIDS IN LIVER-TISSUE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH NEGATIVE-ION CHEMICAL IONIZATION DETECTION [J].
GOTO, J ;
MIURA, H ;
INADA, M ;
NAMBARA, T ;
NAGAKURA, T ;
SUZUKI, H .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :119-129
[6]   STUDIES ON STEROIDS .242. SEPARATION OF C-25 EPIMERS OF 5-BETA-CHOLESTANOIC ACIDS BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH PRECOLUMN FLUORESCENCE LABELING [J].
GOTO, J ;
SHAO, G ;
MIURA, H ;
NAMBARA, T .
ANALYTICAL SCIENCES, 1989, 5 (01) :19-22
[7]   Rat liver bile acid CoA:amino acid N-acyltransferase:: expression, characterization, and peroxisomal localization [J].
He, DN ;
Barnes, S ;
Falany, CN .
JOURNAL OF LIPID RESEARCH, 2003, 44 (12) :2242-2249
[8]  
IIDA T, 1989, J LIPID RES, V30, P1267
[9]   Separation and detection of bile acid 24-glucuronides in human urine by liquid chromatography combined with electrospray ionization mass spectrometry [J].
Ikegawa, S ;
Okuyama, H ;
Oohashi, J ;
Murao, N ;
Goto, J .
ANALYTICAL SCIENCES, 1999, 15 (07) :625-631
[10]  
Ikegawa S, 1996, BIOMED CHROMATOGR, V10, P313, DOI 10.1002/(SICI)1099-0801(199611)10:6<313::AID-BMC603>3.0.CO