Effects of a stereotactic headframe assembly on proton magnetic resonance spectroscopy

被引:3
作者
Campeau, NG [1 ]
Wood, CP [1 ]
Erickson, BJ [1 ]
Jack, CR [1 ]
Felmlee, JP [1 ]
机构
[1] Mayo Clin, Dept Diagnost Radiol, Rochester, MN USA
关键词
magnetic resonance; spectroscopy; stereotactic localization; imaging; stereotactic techniques;
D O I
10.1159/000029663
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The effects of a magnetic resonance-compatible stereotactic headframe assembly on single voxel proton magnetic resonance spectroscopy (MRS) were investigated. Multiple stimulated echo acquisition mode (STEAM) spectra were obtained within a commercially available brain metabolite phantom placed within the headframe assembly (Leksell, Model G). All acquisition parameters were kept constant, except voxel location. Maximal distortion occurred for voxels acquired in the immediate vicinity of a headframe fixation pin, manifested by spectral broadening, changes in peak area and height and distortion of the baseline, rendering these acquisitions nondiagnostic, The range of this interaction was short, and a voxel acquired with nearest edge located 2.0 cm or greater from the fixation pin tip produced NAA/Cr, Cho/Cr and mI/Cr ratios differing by less than 7.5% from a spectrum obtained at the phantom center. The feasibility of performing single voxel MRS with a stereotactic headframe in place is demonstrated.
引用
收藏
页码:190 / 202
页数:13
相关论文
共 14 条
[1]   Errors in MR stereotaxy due to undetected extraneous metal objects [J].
Condon, B ;
Hadley, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (09) :1779-1789
[2]   LOCALIZED HIGH-RESOLUTION PROTON NMR-SPECTROSCOPY USING STIMULATED ECHOES - INITIAL APPLICATIONS TO HUMAN-BRAIN INVIVO [J].
FRAHM, J ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD ;
HANICKE, W ;
SAUTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :79-93
[3]   RADIOFREQUENCY CINGULOTOMY FOR INTRACTABLE CANCER PAIN USING STEREOTAXIS GUIDED BY MAGNETIC-RESONANCE-IMAGING [J].
HASSENBUSCH, SJ ;
PILLAY, PK ;
BARNETT, GH .
NEUROSURGERY, 1990, 27 (02) :220-223
[4]   STEREOTAXIC MAGNETIC-RESONANCE ANGIOGRAPHY FOR TARGETING IN ARTERIOVENOUS MALFORMATION RADIOSURGERY [J].
KONDZIOLKA, D ;
LUNSFORD, LD ;
KANAL, E ;
TALAGALA, L .
NEUROSURGERY, 1994, 35 (04) :585-590
[5]   A COMPARISON BETWEEN MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY FOR STEREOTAXIC COORDINATE DETERMINATION [J].
KONDZIOLKA, D ;
DEMPSEY, PK ;
LUNSFORD, D ;
HEILBRUN, MP ;
KESTLE, JRW ;
DOLAN, EJ ;
KANAL, E ;
TASKER, RR .
NEUROSURGERY, 1992, 30 (03) :402-407
[6]   STEREOTAXIS AND NUCLEAR MAGNETIC-RESONANCE [J].
LEKSELL, L ;
LEKSELL, D ;
SCHWEBEL, J .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1985, 48 (01) :14-18
[7]   STEREOTAXIC SURGERY WITH A MAGNETIC RESONANCE-COMPATIBLE AND COMPUTERIZED TOMOGRAPHY-COMPATIBLE SYSTEM [J].
LUNSFORD, LD ;
MARTINEZ, AJ ;
LATCHAW, RE .
JOURNAL OF NEUROSURGERY, 1986, 64 (06) :872-878
[8]  
LUNSFORD LD, 1998, TXB STEREOTACTIC FUN, P51
[9]  
PETERS TM, 1987, APPL NEUROPHYSIOL, V50, P33
[10]   Accurate, noninvasive diagnosis of human brain tumors by using proton magnetic resonance spectroscopy [J].
Preul, MC ;
Caramanos, Z ;
Collins, DL ;
Villemure, JG ;
Leblanc, R ;
Olivier, A ;
Pokrupa, R ;
Arnold, DL .
NATURE MEDICINE, 1996, 2 (03) :323-325