Gastrointestinal sutureless anastomosis using fibrin glue: Reinforcement of the sliding absorbable intraluminal nontoxic stent and development of a stent placement device

被引:8
作者
Detweiler, MB
Verbo, A
Kobos, JW
Durastante, V
Pignoli, V
Granone, P
Magistrelli, P
Picciocchi, A
机构
[1] UNIV CATTOLICA SACRO CUORE, SCH MED, DEPT SURG 1, AGOSTINO GEMELLI HOSP, I-00168 ROME, ITALY
[2] MED ACAD LODZ, DEPT PATHOL, LODZ, POLAND
[3] ITALIAN ARMY SCH ARTILLERY, BRACCIANO, ITALY
关键词
absorbable intraluminal stent; anastomosis; enteroenterostomy; fibrin glue; stent placement device; sutureless stapler; swine;
D O I
10.3109/08941939609012464
中图分类号
R61 [外科手术学];
学科分类号
摘要
Sutureless anastomosis of the gastrointestinal tract using fibrin glue and sliding absorbable intraluminal nontoxic stents (SAINTs) has two shortcomings, stent shaft breakage and the lack of a transanal insertion device (TID) for low anterior resection. Reinforcement of the sucrose base SAINT (R-SAINT) is described. Sutureless anastomosis is attempted using a stapleless mechanical stapler (SS) and used as preprototype to screen histologically and mechanically for TID anastomoses in the small intestine. Finally, a prototype absorbable head SAINT placement device (SAINT-PD) intended for TID, similar to the SS, is utilized on the small intestine. Fifty-seven Landrace pigs weighing 25-35 kg were used to perform 58 anastomoses, including the small intestine (15 manual, 19 SAINT, 11 SS, 5 R-SAINT, 6 SAINT-PD) and large intestine (2 R-SAINT). All anastomoses performed with the R-SAINT succeeded on the first attempt even if the shaft cracked. The SS technique proved impractical, but the histological screen results from 7 to 60 days did approximate those of corresponding SAINT anastomoses. The SAINT-PD demonstrated operational impr ovement over the SS, but the histological results were similar to both the SS and SAINT. The advantages of the R-SAINT and SAINT-PD are that they leave no foreign bodies or pressure clamping devices at the anastomostic site. Larger studies may show the R-SAINT and the SAINT-PD to be practical, new surgical tools in sutureless fibrin glue anastomosis.
引用
收藏
页码:111 / 130
页数:20
相关论文
共 28 条
[1]  
ALLEN WJ, 1994, Patent No. 5282810
[2]  
[Anonymous], 1892, Med Rec
[3]   INTESTINAL SUTURING - REVIEW OF THE EXPERIMENTAL FOUNDATIONS FOR TRADITIONAL DOCTRINES [J].
BALLANTYNE, GH .
DISEASES OF THE COLON & RECTUM, 1983, 26 (12) :836-843
[4]   THE EXPERIMENTAL BASIS OF INTESTINAL SUTURING - EFFECT OF SURGICAL TECHNIQUE, INFLAMMATION, AND INFECTION ON ENTERIC WOUND-HEALING [J].
BALLANTYNE, GH .
DISEASES OF THE COLON & RECTUM, 1984, 27 (01) :61-71
[5]  
BASS LS, 1993, Patent No. 5209776
[6]  
BROWN SG, 1983, WORLD J SURG, V7, P700
[7]   PROSPECTIVE, RANDOMIZED TRIAL OF THE BIOFRAGMENTABLE ANASTOMOSIS RING [J].
BUBRICK, MP ;
CORMAN, ML ;
CAHILL, CJ ;
HARDY, TG ;
NANCE, FC ;
SHATNEY, CH .
AMERICAN JOURNAL OF SURGERY, 1991, 161 (01) :136-143
[8]  
BUSU S, 1988, J VASC SURG, V7, P420
[9]   SUTURELESS LARGE BOWEL ANASTOMOSIS - EUROPEAN-EXPERIENCE WITH THE BIOFRAGMENTABLE ANASTOMOSIS RING [J].
CAHILL, CJ ;
BETZLER, M ;
GRUWEZ, JA ;
JEEKEL, J ;
PATEL, JC ;
ZEDERFELDT, B .
BRITISH JOURNAL OF SURGERY, 1989, 76 (04) :344-347
[10]   COMPARISON OF THE VALTRAC BIOFRAGMENTABLE ANASTOMOSIS RING WITH CONVENTIONAL SUTURE AND STAPLED ANASTOMOSIS IN COLON SURGERY - RESULTS OF A PROSPECTIVE, RANDOMIZED CLINICAL-TRIAL [J].
CORMAN, ML ;
PRAGER, ED ;
HARDY, TG ;
BUBRICK, MP .
DISEASES OF THE COLON & RECTUM, 1989, 32 (03) :183-187