Capillary electrochromatography of proteins and peptides with porous layer open-tubular columns

被引:124
作者
Huang, X [1 ]
Zhang, J [1 ]
Horváth, C [1 ]
机构
[1] Yale Univ, Dept Chem Engn, New Haven, CT 06520 USA
关键词
capillary columns; porous-layer open-tubular columns; electrochromatography; proteins; peptides;
D O I
10.1016/S0021-9673(99)00795-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrochromatography (CEC) of basic proteins and peptides was carried out with porous-layer open-tubular (PLOT) columns which had a functionalized rugulose polymeric porous layer grafted to the innerwall of 20 mu m I.D. fused-silica capillaries. The porous layer was highly crosslinked and prepared by in situ polymerization of vinylbenzyl chloride and divinylbenzene in the presence of 2-octanol as a porogen inside a pretreated fused-silica capillary. The chloromethyl functions at the surface of the porous polymeric support layer were reacted with N,N-dimethyldodecylamine to obtain a positively charged chromatographic surface with fixed C-12 alkyl chains. A mixture of lysozyme, cytochrome c, ribonuclease A and alpha-chymotrypsinogen A was separated isocratically by counterdirectional CEC with hydro-organic mobile phases containing acetonitrile and phosphate buffer, pH 2.5. The overall migration behavior of the four proteins was the result of an interplay of chromatographic retention and electrophoretic migration, and was different from that observed in capillary zone electrophoresis or in reversed-phase chromatography under similar conditions. The separation of three basic peptides by CEC also exhibited the same behavior. The stability of the PLOT column was tested by measuring electroosmotic mobility during continual use. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 27 条
[1]  
Altria KD, 1998, LC GC-MAG SEP SCI, V16, P548
[2]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[3]   ELECTRICALLY DRIVEN OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
BRUIN, GJM ;
TOCK, PPH ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 517 :557-572
[4]   Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries [J].
Choudhary, G ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :161-183
[5]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[6]   Fritless packed columns for capillary electrochromatography: Separation of uncharged compounds on hydrophobic hydrogels [J].
Fujimoto, C ;
Fujise, Y ;
Matsuzawa, E .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2753-2757
[7]  
GUIOCHON G, 1980, HIGH PERFORMANCE LIQ, P1
[8]   OPEN TUBE COLUMNS WITH IMPREGNATED THIN LAYER SUPPORT FOR GAS CHROMATOGRAPHY [J].
HALASZ, I ;
HORVATH, C .
ANALYTICAL CHEMISTRY, 1963, 35 (04) :499-&
[9]   THIN-LAYER GRAPHITED CARBON BLACK AS STATIONARY PHASE FOR CAPILLARY COLUMNS IN GAS CHROMATOGRAPHY [J].
HALASZ, I ;
HORVATH, C .
NATURE, 1963, 197 (486) :71-&
[10]  
HORVATH C, 1997, P 19 INT S CAP CHROM, P60