Fusion Viewer: A New Tool for Fusion and Visualization of Multimodal Medical Data Sets

被引:30
作者
Baum, Karl G. [1 ]
Helguera, Maria [1 ]
Krol, Andrzej [2 ]
机构
[1] Rochester Inst Technol, Chester F Carlson Ctr Imaging Sci, Rochester, NY 14623 USA
[2] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY USA
关键词
Multimodality visualization; fusion visualization; multimodal imaging; image fusion; clinical image viewing; image viewer; image visualization; image display; contrast enhancement; image contrast; volume visualization; imaging; three-dimensional; image analysis; biomedical image analysis; image enhancement; cancer detection; breast; algorithms;
D O I
10.1007/s10278-007-9082-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new application, Fusion Viewer, available for free, has been designed and implemented with a modular object-oriented design. The viewer provides both traditional and novel tools to fuse 3D data sets such as CT (computed tomography), MRI (magnetic resonance imaging), PET (positron emission tomography), and SPECT (single photon emission tomography) of the same subject, to create maximum intensity projections (MIP) and to adjust dynamic range. In many situations, it is desirable and advantageous to acquire biomedical images in more than one modality. For example, PET can be used to acquire functional data, whereas MRI can be used to acquire morphological data. In some situations, a side-by-side comparison of the images provides enough information, but in most of the cases it may be necessary to have the exact spatial relationship between the modalities presented to the observer. To accomplish this task, the images need to first be registered and then combined (fused) to create a single image. In this paper, we discuss the options for performing such fusion in the context of multimodal breast imaging. Additionally, a novel spline-based dynamic range technique is presented in detail. It has the advantage of obtaining a high level of contrast in the intensity range of interest without discarding the intensity information outside of this range while maintaining a user interface similar to the standard window/level windowing procedure.
引用
收藏
页码:S59 / S68
页数:10
相关论文
共 19 条
[1]   Intensity-modulated parametric mapping for simultaneous display of rapid dynamic and high-spatial-resolution breast MR imaging data [J].
Agoston, AT ;
Daniel, BL ;
Herfkens, RJ ;
Ikeda, DM ;
Birdwell, RL ;
Heiss, SG ;
Sawyer-Glover, AM .
RADIOGRAPHICS, 2001, 21 (01) :217-226
[2]   Techniques for fusion of multimodal images: Application to breast imaging [J].
Baum, Karl G. ;
Helguera, Maria ;
Hornak, Joseph P. ;
Kerekes, John P. ;
Montag, Ethan D. ;
Unlu, Mehmet Z. ;
Feiglin, David H. ;
Krol, Andrzej .
2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, :2521-+
[3]   A new application for displaying and fusing multimodal data sets [J].
Baum, Karl G. ;
Helguera, Maria ;
Krol, Andrzej .
MULTIMODAL BIOMEDICAL IMAGING II, 2007, 6431
[4]  
BAUM KG, 2006, P IS T SIDS 14 COL I, P138
[5]  
DROLON H, FREEIMAGE
[6]  
DROLON H, FREEIMAGE DOCUMENTAT
[7]   Chest CT window settings with multiscale adaptive histogram equalization: Pilot study [J].
Fayad, LM ;
Jin, YP ;
Laine, AF ;
Berkmen, YM ;
Pearson, GD ;
Freedman, B ;
Van Heertum, R .
RADIOLOGY, 2002, 223 (03) :845-852
[8]  
Gonzalez R., 2019, Digital Image Processing, V2nd
[9]   Generalized dynamic range compression algorithm for visualization of chest CT images [J].
Hara, S ;
Shimura, K ;
Nagata, T .
MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 :578-585
[10]  
JIN Y, 2000, P SPIE INT SOC OPT E, V4478, P206