Development of QCM biosensor to detect a marine derived pathogenic bacteria Edwardsiella tarda using a novel immobilisation method

被引:48
作者
Hong, Sung-Rok [1 ]
Choi, Suk-Jung [1 ]
Do Jeong, Hyun [2 ]
Hong, Suhee [1 ]
机构
[1] Kangnung Natl Univ, Dept Chem, Fac Marine Biosci & Technol, Kangnung 210702, South Korea
[2] Pukyong Natl Univ, Dept Aquat Life Med, Pusan 608737, South Korea
关键词
QC; Immunosensor; Immobilisation; Regeneration; Edwardsiella tarda; QUARTZ-CRYSTAL MICROBALANCE; PIEZOELECTRIC IMMUNOSENSOR; SALMONELLA-TYPHIMURIUM; FLUORESCENCE; ANTIBODIES; PROTEIN; SENSOR; FISH;
D O I
10.1016/j.bios.2008.08.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
QCM technology offers a real time output, simplicity of use and cost effectiveness in addition to high sensitivity. Sensitivity of QCM immunosensor can be enhanced by improving the immobilisation procedure on the quartz surface. The immobilisation strategy should be able to control both the amount and the orientation of the antibody (immunoglobulin; IgG) on the transducer for high affinity to antigens. This study introduced a new methodology recruiting oxidised IgG to expose aldehyde group in Fc region to cross-link to hydrazide conformed on self assembled monolayer (SAM) and compared with three conventional methods. Consequently, it was proved that considerable amount of antibody was immobilised and the sensitivity of new methodology was higher than other methods while ability of new methodology to immobilise IgG was lower than the conventional methods. The frequency shifts following bacterial cell injection were positively related to the frequency shifts after the injection of IgG and the amounts of bacterial cells, revealing that the frequency shifts after bacterial cell injection fully represented the weight change by specific attachments of bacterial cells to the IgG cross-linked on the gold surface. Specificity was tested on different bacteria including E. coli, V vulnificus and A. hydrophila and showed no significant non-specific affinity on the tested bacteria. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration. Indeed, polyclonal antibody was more effective to detect antigen than monoclonal antibody which binds to only one epitope of antigen. Conclusively, the new methodology is appeared to be more sensitive than conventional methods tested and reusable for 10 times. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1635 / 1640
页数:6
相关论文
共 33 条
[1]   ISOLATION AND CHARACTERIZATION OF EDWARDSIELLA-TARDA FROM FALL CHINOOK SALMON (ONCORHYNCHUS-TSHAWYTSCHA) [J].
AMANDI, A ;
HIU, SF ;
ROHOVEC, JS ;
FRYER, JL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (06) :1380-1384
[2]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[3]   Determination of microorganisms with a quartz crystal microbalance sensor [J].
Bao, LL ;
Deng, L ;
Nie, LH ;
Yao, SZ ;
Wei, WZ .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :97-101
[4]   Functionalisation of gold surfaces with thiolate SAMs: Topography/bioactivity relationship - A combined FT-RAIRS, AFM and QCM investigation [J].
Briand, E. ;
Gu, C. ;
Boujday, S. ;
Salmain, M. ;
Herry, J. M. ;
Pradier, C. M. .
SURFACE SCIENCE, 2007, 601 (18) :3850-3855
[5]   Piezoelectric quartz crystal biosensors [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 1998, 46 (06) :1223-1236
[6]   PCR-based assays for the fish pathogen Aeromonas salmonicida.: II.: Further evaluation and validation of three PCR primer sets with infected fish [J].
Byers, HK ;
Cipriano, RC ;
Gudkovs, N ;
Crane, MS .
DISEASES OF AQUATIC ORGANISMS, 2002, 49 (02) :139-144
[7]  
CLARKE DJ, 1987, BIOSENSORS FUNDAMENT, P551
[8]   Novel biosensor chip for simultaneous detection of DNA-carcinogen adducts with low-temperature fluorescence [J].
Grubor, NM ;
Shinar, R ;
Jankowiak, R ;
Porter, MD ;
Small, GJ .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :547-556
[9]   A PIEZOELECTRIC IMMUNOBIOSENSOR FOR ATRAZINE IN DRINKING-WATER [J].
GUILBAULT, GG ;
HOCK, B ;
SCHMID, R .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) :411-419
[10]   An amperometric biosensor for real-time analysis of molecular recognition [J].
Ivnitski, D ;
Wolf, T ;
Solomon, B ;
Fleminger, G ;
Rishpon, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (01) :27-32