Identification of systems failures in successful paediatric cardiac surgery

被引:129
作者
Catchpole, K. R. [1 ]
Giddings, A. E. B.
De Leval, M. R.
Peek, G. J.
Godden, P. J.
Utley, M.
Gallivan, S.
Hirst, G.
Dale, T.
机构
[1] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Surg, Oxford OX3 9DU, England
[2] Royal Coll Surgeons England, London WC2A 3PE, England
[3] Great Ormond St Hosp Sick Children, Cardiothorac Unit, London WC1N 3JH, England
[4] Univ Hosp Leicester NHS Trust, Glenfield Gen Hosp, Leicester, Leics, England
[5] UCL, Clin Operat Res Unit, London, England
[6] Atrainabil Ltd, Surrey, England
关键词
error; surgery; observation; health care; safety;
D O I
10.1080/00140130600568865
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Patient safety will benefit from an approach to human error that examines systemic causes, rather than blames individuals. This study describes a direct observation methodology, based on a threat and error model, prospectively to identify types and sources of systems failures in paediatric cardiac surgery. Of substantive interest were the range, frequency and types of failures that could be identified and whether minor failures could accumulate to form more serious events, as has been the case in other industries. Check lists, notes and video recordings were employed to observe 24 successful operations. A total of 366 failures were recorded. Coordination and communication problems, equipment problems, a relaxed safety culture, patient-related problems and perfusion-related problems were most frequent, with a smaller number of skill, knowledge and decision-making failures. Longer and more risky operations were likely to generate a greater number of minor failures than shorter and lower risk operations, and in seven higher-risk cases frequently occurring minor failures accumulated to threaten the safety of the patient. Non-technical errors were more prevalent than technical errors and task threats were the most prevalent systemic source of error. Adverse events in surgery are likely to be associated with a number of recurring and prospectively identifiable errors. These may be co-incident and cumulative human errors predisposed by threats embedded in the system, rather than due to individual incompetence or negligence. Prospectively identifying and reducing these recurrent failures would lead to improved surgical standards and enhanced patient safety.
引用
收藏
页码:567 / 588
页数:22
相关论文
共 83 条
[11]   Adverse events in cardiac surgery: The role played by human and organisational factors [J].
Carthey, J ;
de Leval, M ;
Reason, J ;
Leggatt, A ;
Wright, D .
SAFETY IN MEDICINE, 2000, :117-138
[12]  
CARTHEY J, 2001, CLIN RISK, V7, P85
[13]   Localizable auditory warning pulses [J].
Catchpole, K ;
McKeown, JD ;
Withington, DJ .
ERGONOMICS, 2004, 47 (07) :748-771
[14]  
CATCHPOLE K, 2005, PS012 PAT SAF RES PR
[15]  
CATCHPOLE KR, 1999, ENG PSYCHOL PSYCHOL, P439
[16]  
CATCHPOLE KR, 2001, IDENTIFICATION FACTO, P17
[17]   Adapting to new technology in the operating room [J].
Cook, RI .
HUMAN FACTORS, 1996, 38 (04) :593-613
[18]  
Cook RI, 1994, HUMAN ERROR MED, P255, DOI DOI 10.1201/9780203751725-13
[19]   PREVENTABLE ANESTHESIA MISHAPS - STUDY OF HUMAN-FACTORS [J].
COOPER, JB ;
MCPEEK, B ;
LONG, CD ;
NEWBOWER, RS .
ANESTHESIOLOGY, 1978, 49 (06) :399-406
[20]  
Cuschieri A, 2000, ANN ROY COLL SURG, V82, P83