摘要
The development of a rapid method for the determination of perchlorate in rain and drinking waters is presented. In the optimised method, an on-line preconcentration technique was employed utilising a 10 mm x 4.6 mm Phenomenex Onyx monolithic guard cartridge coated with (N-dodecyl-N,N-dimethylammonio)undecanoate for selective preconcentration, with subsequent elution into a fixed volume injection loop ('heart-cut' of the concentrator column eluate) and separation using an IonPac AS 16 (250 mm x 2 mm) anion exchange column and a potassium hydroxide concentration gradient. Off-line optimisation studies showed that the coated monolith displayed near quantitative recovery up to 50 mu g/L perchlorate level from standards prepared in reagent water. On-line preconcentration of perchlorate obtained detection limits down to 56 ng/L in reagent water, between 70 and 80 ng/L in rainwater samples and 2.5 mu g/L in non-pretreated drinking water. After an additional sample sulphate/carbonate removal step, low ng/L perchlorate concentrations could also be observed in drinking water. The complete on-line method exhibited reproducibility for n = 10 replicate runs of R.S.D. <= 3% for peak height/area and R.S.D. = 0.08% for retention time. The optimised method, of 20 min total duration, was applied to the determination of perchlorate by standard addition in 10 rainwater samples and one drinking water sample. Concentrations of perchlorate present ranged from below the detection limit for four rainwater samples, with another three samples showing perchlorate present at between 70 and 100 ng/L, and one sample showing perchlorate present at 2.8 mu g/L. Levels of 1.1 mu g/L in the drinking water sample were also recorded. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 31 条
[1]   Regulation of the L1 cell adhesion molecule by thyroid hormone in the developing brain [J].
Alvarez-Dolado, M ;
Cuadrado, A ;
Navarro-Yubero, C ;
Sonderegger, P ;
Furley, AJ ;
Bernal, J ;
Muñoz, A .
MOLECULAR AND CELLULAR NEUROSCIENCE, 2000, 16 (04) :499-514
[2]  
BARRON L, IN PRESS TALANTA
[3]   ION CHROMATOGRAPHIC DETERMINATION OF PERCHLORATE IN CATTLE URINE [J].
BATJOENS, P ;
DEBRABANDER, HF ;
TKINDT, L .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :335-340
[4]   Rapid, low pressure, and simultaneous ion chromatography of common inorganic anions and cations on short permanently coated monolithic columns [J].
Connolly, D ;
Victory, D ;
Paull, B .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :912-920
[5]   The origin of naturally occurring perchlorate: The role of atmospheric processes [J].
Dasgupta, PK ;
Martinelango, PK ;
Jackson, WA ;
Anderson, TA ;
Tian, K ;
Tock, RW ;
Rajagopalan, S .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (06) :1569-1575
[6]  
Dowling ALS, 2000, J NEUROSCI, V20, P2255
[7]   Determination of perchlorate at parts-per-billion levels in plants by ion chromatography [J].
Ellington, JJ ;
Evans, JJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 898 (02) :193-199
[8]   Determination of perchlorate in tobacco plants and tobacco products [J].
Ellington, JJ ;
Wolfe, NL ;
Garrison, AW ;
Evans, JJ ;
Avants, JK ;
Teng, QC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3213-3218
[9]  
Haddow JE, 1999, NEW ENGL J MED, V341, P2017
[10]   Improved sensitivity and characterization of high-speed ion chromatography of inorganic anions [J].
Hatsis, P ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :995-1001