A new method of concentrating hepatitis B virus (HBV) DNA and HBV surface antigen: an application of the method to the detection of occult HBV infection

被引:29
作者
Satoh, K. [1 ]
Iwata-Takakura, A. [1 ]
Yoshikawa, A. [1 ]
Gotanda, Y. [1 ]
Tanaka, T. [2 ]
Yamaguchi, T. [3 ]
Mizoguchi, H. [1 ]
机构
[1] Japanese Red Cross Saitama Blood Ctr, Hidaka, Saitama 3501213, Japan
[2] Tokyo Womens Med Univ, IREIIMS, Shinjuku Ku, Tokyo, Japan
[3] Natl Inst Hlth Sci, Div Biol Chem & Biol, Setagaya Ku, Tokyo, Japan
关键词
anti-HBc; concentration of HBV DNA; concentration of HBsAg; occult HBV infection; poly-L-lysine-coated magnetic beads;
D O I
10.1111/j.1423-0410.2008.01091.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background The risk of post-transfusion hepatitis B virus (HBV) infection has been reduced after the implementation of HBV nucleic acid amplification technology (NAT). However, the problem of HBV DNA-positive and HBV surface antigen (HBsAg)-negative occult HBV infections remains to be solved. This is in part due to the HBV DNA load being too low to detect these occult HBV infections using mini-pool NAT. In Japan, the assay for the antibody against the HBV core antigen (anti-HBc) has not completely excluded occult HBV infection. To solve this problem, we have developed a new method of concentrating HBV DNA and HBsAg simultaneously to increase the sensitivity of detection tests. Methods Virus concentration is achieved by the enhancement of the agglutination of viruses using poly-L-lysine in the presence of a bivalent metal. Poly-L-lysine-coated magnetic beads are used to shorten the time of each step of the concentration procedure. Seventy-seven anti-HBc-positive and HBsAg-negative donations were examined. HBsAg and anti-HBc were tested by enzyme immunoassay (EIA) (AxSYM; Abbott) and haemagglutination inhibition test (Japanese Red Cross), respectively. Results HBV surface antigen and HBV DNA levels were concentrated up to four- to sevenfold. Using this method, 35 of the 77 anti-HBc-positive and HBsAg-negative donors were HBV DNA-positive by individual NAT and a further five donors became HBV DNA-positive by HBV concentration. Twenty-seven of 40 occult HBV infections became HBsAg-positive by HBsAg concentration. Conclusion Our new method of concentrating HBV and HBsAg increased the sensitivities of EIA and HBV NAT, and enabled us to detect 27 of 40 occult HBV infections by HBsAg EIA.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 27 条
[1]
Lack of correlation between hepatitis B surface antigen and hepatitis B virus DNA levels in blood donors [J].
Allain, JP ;
Sarkodie, F ;
Candotti, D ;
Opare-Sem, O .
TRANSFUSION, 2005, 45 (06) :1039-1040
[2]
Occult hepatitis B virus infection: implications in transfusion [J].
Allain, JP .
VOX SANGUINIS, 2004, 86 (02) :83-91
[3]
Ultracentrifugation of serum samples allows detection of hepatitis C virus RNA in patients with occult hepatitis C [J].
Bartolome, Javier ;
Manuel Lopez-Alcorocho, Juan ;
Castillo, Inmaculada ;
Rodriguez-Inigo, Elena ;
Antonio Quiroga, Juan ;
Palacios, Ricardo ;
Carreno, Vicente .
JOURNAL OF VIROLOGY, 2007, 81 (14) :7710-7715
[4]
Comparative sensitivity of HBVNATs and HBsAg assays for detection of acute HBV infection [J].
Biswas, R ;
Tabor, E ;
Hsia, CC ;
Wright, DJ ;
Laycock, ME ;
Fiebig, EW ;
Peddada, L ;
Smith, R ;
Schreiber, GB ;
Epstein, JS ;
Nemo, GJ ;
Busch, MP .
TRANSFUSION, 2003, 43 (06) :788-798
[5]
Sensitivity of hepatitis B virus DNA transcription-mediated amplification testing in hepatitis B surface antigen-positive blood donations [J].
Bouchardeau, Francoise ;
Girault, Annie ;
Razer, Annie ;
Servant-Delmas, Annabelle ;
Mercier, Melanie ;
Laperche, Syria .
TRANSFUSION, 2006, 46 (12) :2047-2052
[6]
Hepatitis B surface antigen (HBsAg) assays - Are they good enough for their current uses? [J].
Dufour, D. Robert .
CLINICAL CHEMISTRY, 2006, 52 (08) :1457-1459
[7]
Frequency and load of hepatitis B virus DNA in first-time blood donors with antibodies to hepatitis B core antigen [J].
Hennig, H ;
Puchta, I ;
Luhm, J ;
Schlenke, P ;
Goerg, S ;
Kirchner, H .
BLOOD, 2002, 100 (07) :2637-2641
[8]
CORRELATION BETWEEN ANTI-HBC TITERS AND HBV DNA IN BLOOD UNITS WITHOUT DETECTABLE HBSAG [J].
IIZUKA, H ;
OHMURA, K ;
ISHIJIMA, A ;
SATOH, K ;
TANAKA, T ;
TSUDA, F ;
OKAMOTO, H ;
MIYAKAWA, Y ;
MAYUMI, M .
VOX SANGUINIS, 1992, 63 (02) :107-111
[9]
Individual nucleic amplification technology does not prevent all hepatitis B virus transmission by blood transfusion [J].
Inaba, Shoichi ;
Ito, Akira ;
Miyata, Yoshihisa ;
Ishii, Hiroyuki ;
Kajimoto, Shoko ;
Tanaka, Masatsugu ;
Maruta, Atsuo ;
Saito, Satoru ;
Yugi, Hisao ;
Hino, Minabu ;
Tadokoro, Kenji .
TRANSFUSION, 2006, 46 (11) :2028-2029
[10]
Virus concentration using polyethyleneimine-conjugated magnetic beads for improving the sensitivity of nucleic acid amplification tests [J].
Iwata, A ;
Murata, M ;
Hikata, M ;
Hayakawa, T ;
Yamaguchi, T .
JOURNAL OF VIROLOGICAL METHODS, 2003, 114 (01) :11-19