Bovine pericardial versus porcine stented replacement aortic valves: Early results of a randomized comparison of the Perimount and the Mosaic valves

被引:39
作者
Chambers, John B. [1 ]
Rajani, Ronak [1 ]
Parkin, Denise [1 ]
Rimington, Helen M. [1 ]
Blauth, Christopher I. [1 ]
Venn, Graham E. [1 ]
Young, Christopher P. [1 ]
Roxburgh, James C. [1 ]
机构
[1] Guys & St Thomas Hosp, Ctr Cardiothorac, London SE1 9RT, England
关键词
D O I
10.1016/j.jtcvs.2007.12.086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: A stented bovine pericardial valve might be less obstructive than a stented porcine valve. This study compared early hemodynamic function in a prospective series of 99 patients randomized to receive either a Mosaic or Perimount replacement aortic valve. Methods: Echocardiography was performed early after surgery and at 1 year after surgery. Patients also filled in psychologic questionnaires and underwent a 6-minute walk. Results: The groups were matched demographically. The Perimount valve was significantly less obstructive in terms of mean pressure difference (11 6 5 vs 17 6 7 mm Hg; P<.0001), with a trend in favor of a larger effective orifice area (1.47 +/- 6 0.45 vs 1.28 +/- 6 0.46 cm(2); P = 5.05) postoperatively. There were no differences in left ventricular mass regression, aortic regurgitation, 6-minute walk, psychologic questionnaires, or mortality and clinical events. Conclusion: The stented bovine pericardial valve was less obstructive than the stented porcine valve. Both valves were associated with similar and significant improvements in quality of life, exercise ability, and regression of left ventricular mass.
引用
收藏
页码:1142 / 1148
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 2001, SF 36 PHYS MENTAL HL
[2]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[3]   2-MINUTE, 6-MINUTE, AND 12-MINUTE WALKING TESTS IN RESPIRATORY-DISEASE [J].
BUTLAND, RJA ;
PANG, J ;
GROSS, ER ;
WOODCOCK, AA ;
GEDDES, DM .
BRITISH MEDICAL JOURNAL, 1982, 284 (6329) :1607-1608
[4]   A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events [J].
Chambers, J ;
Roxburgh, J ;
Blauth, C ;
O'Riordan, J ;
Hodson, F ;
Rimington, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (03) :759-764
[5]   Discrepancies between labeled and actual dimensions of prosthetic valves and sizers [J].
Cochran, RP ;
Kunzelman, KS .
JOURNAL OF CARDIAC SURGERY, 1996, 11 (05) :318-324
[6]  
Corbineau H, 2001, J HEART VALVE DIS, V10, P171
[7]  
Dalmau Maria Jose, 2007, Interact Cardiovasc Thorac Surg, V6, P345, DOI 10.1510/icvts.2006.144196
[8]   Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis [J].
Dellgren, G ;
David, TE ;
Raanani, E ;
Armstrong, S ;
Ivanov, J ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) :146-154
[9]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[10]   Guidelines for reporting morbidity and mortality after cardiac valvular operations [J].
Edmunds, LH ;
Clark, RE ;
Cohn, LH ;
Grunkemeier, GL ;
Miller, C ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :932-935