MR-guided RF thermal ablation of the kidney in a porcine model

被引:40
作者
Merkle, EM
Shonk, JR
Duerk, JL
Jacobs, GH
Lewin, JS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Radiol, Div MRI, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Pathol, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Oncol, Cleveland, OH 44106 USA
关键词
D O I
10.2214/ajr.173.3.10470895
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The purpose of the study was to evaluate the ability of MR imaging to reveal RF interstitial thermotherapy in the porcine kidney, as a model for future human trials, and to provide guidance far RF probe insertion. SUBJECTS AND METHODS. Ten MR-guided RF ablations were performed in the kidneys of three pigs. A 17-gauge monopolar RF probe electrode was inserted into the renal cortex using MR guidance, and RF was applied for 10 min. After postprocedure imaging (T2-weighted, turbo short inversion time inversion recovery [STIR], and T1-weighted sequences), the kidneys were harvested for pathologic examination. RESULTS. Successful RF probe placement was accomplished in all cases; the interventional procedure time for probe insertion ranged from 4 to 15 min. The thermal lesion size varied from 7 to lt mm perpendicular to the probe track and was best seen on turbo STIR images. Turbo STIR had the highest renal cortex-to-RF thermal lesion contrast-to-noise ratio with an average of 4.4 +/- 3.5. Turbo STIR imaging never overestimated pathologic lesion diameter with a mean difference of 1.5 +/- 1.4 mm. Three subcapsular hematomas occurred, which could be detected immediately on postprocedure imagine. CONCLUSION. MR-guided RF thermal ablation in thee porcine kidney was found to be feasible, but minor complications occurred. Induced thermal lesion size was best monitored using turbo STIR images. Zn the future, RF ablation may offer an alternative treatment option for renal cancer.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 35 条
[1]  
ANZAI Y, 1995, AM J NEURORADIOL, V16, P39
[2]   THE USE OF RADIO-FREQUENCY POWER IN MAKING LESIONS IN THE BRAIN [J].
ARONOW, S .
JOURNAL OF NEUROSURGERY, 1960, 17 (03) :431-438
[3]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[4]   Problems in the detection and characterization of small renal masses [J].
Bosniak, MA ;
Rofsky, NM .
RADIOLOGY, 1996, 200 (01) :286-287
[5]   Renal cryosurgery: Experimental evaluation of treatment parameters [J].
Campbell, SC ;
Krishnamurthi, V ;
Chow, G ;
Hale, J ;
Myles, J ;
Novick, AC .
UROLOGY, 1998, 52 (01) :29-33
[6]   Monitoring renal cryosurgery: Predictors of tissue necrosis in swine [J].
Chosy, SG ;
Nakada, SY ;
Lee , FT ;
Warner, TF .
JOURNAL OF UROLOGY, 1998, 159 (04) :1370-1374
[7]   The future of research in genitourinary radiology: Through the looking glass - A view from the Society of Uroradiology [J].
Choyke, PL ;
Hricak, H ;
Kenney, PJ ;
Sandler, CM ;
Bush, WH ;
Clark, RL .
RADIOLOGY, 1998, 207 (01) :3-6
[8]   Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging [J].
Chung, YC ;
Duerk, JL ;
Lewin, JS .
INVESTIGATIVE RADIOLOGY, 1997, 32 (08) :466-474
[9]   Cryotherapy for renal cell carcinoma and angiomyolipoma [J].
Vallancien, G .
JOURNAL OF UROLOGY, 1996, 155 (01) :255-255
[10]   EARLY POSTOPERATIVE APPEARANCE OF RADIOFREQUENCY LESIONS ON MAGNETIC-RESONANCE-IMAGING [J].
DESALLES, AAF ;
BREKHUS, SD ;
DESOUZA, EC ;
BEHNKE, EI ;
FARAHANI, K ;
ANZAI, Y ;
LUFKIN, R .
NEUROSURGERY, 1995, 36 (05) :932-936