Possibilities of electricity generation in the Republic of Croatia from medium-temperature geothermal sources

被引:48
作者
Guzovic, Zvonimir [1 ]
Majcen, Boris [2 ]
Cvetkovic, Svetislav [3 ]
机构
[1] Univ Zagreb, Fac Mech Engn & Naval Architecture, Zagreb 10000, Croatia
[2] Elektroprojek Doo, Zagreb 10000, Croatia
[3] Univ Nis, Fac Technol, Leskovac 16000, Serbia
关键词
Geothermal energy; Geothermal power plant; Organic Rankine Cycle (ORC); Kalina cycle; Lunjkovec-Kutnjak; -; Croatia; ORGANIC RANKINE-CYCLE; WORKING FLUIDS; SELECTION; POWER; ORC;
D O I
10.1016/j.apenergy.2012.03.064
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the Republic of Croatia, there are several sources of medium-temperature geothermal water in the range of 90-140 degrees C, with which it is possible to produce electricity in binary plants, either with the Organic Rankine Cycle (ORC) or with the Kalina cycle. In the literature, the Kalina cycle is viewed as more thermodynamically favourable than the ORC; i.e., the Kalina cycle has a higher thermal efficiency and produces more power. However, the Croatian experience with a medium-temperature geothermal source with the relatively high temperature of geothermal water (Velika Ciglena, 175 degrees C) is that the ORC is thermodynamically better than the Kalina cycle. In this paper, a comparison between the ORC and the Kalina cycle is performed based on energy analysis results for a medium-temperature geothermal source with a relatively lower temperature (Lunjkovec-Kutnjak, 140 degrees C). Additionally, in this case the ORC has better thermal efficiency (First Law efficiency) - 13.5% vs. 12.8% - and accordingly higher net power - 2225.5 kW vs. 2101.4 kW. This difference is explained by the relatively high average annual temperature of the cooling air in the condenser (15 degrees C), which has a more unfavourable influence on the condensing pressure in the Kalina cycle than in the ORC (6.35 bar vs. 0.68 bar). (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:404 / 414
页数:11
相关论文
共 31 条
[1]  
Abisa M.T., 2002, 15 UN U
[2]  
[Anonymous], FUT GEOTH EN
[3]  
[Anonymous], 2010, P WORLD GEOTH C
[4]  
[Anonymous], P WORLD GEOTH C BAL
[5]  
[Anonymous], 2006, Advanced Materials and Technologies, DOI DOI 10.1007/B83039
[6]   Comparative analysis of natural and synthetic refrigerants in application to low temperature Clausius-Rankine cycle [J].
Borsukiewicz-Gozdur, Aleksandra ;
Nowak, Wladyslaw .
ENERGY, 2007, 32 (04) :344-352
[7]  
BRONICKI LY, 2004, P GEOTH EN TERR POM
[8]   Analysis and optimization of the low-temperature solar organic Rankine cycle (ORC) [J].
Delgado-Torres, Agustin M. ;
Garcia-Rodriguez, Lourdes .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) :2846-2856
[9]   Process integration of organic Rankine cycle [J].
Desai, Nishith B. ;
Bandyopadhyay, Santanu .
ENERGY, 2009, 34 (10) :1674-1686
[10]  
DiPippo R., 2005, GEOTHERMAL POWER PLA