Development of a compact computed tomographic apparatus for dental use

被引:465
作者
Arai, Y [1 ]
Tammisalo, E [1 ]
Iwai, K [1 ]
Hashimoto, K [1 ]
Shinoda, K [1 ]
机构
[1] Nihon Univ, Sch Dent, Dept Radiol, Chiyoda Ku, Tokyo 101, Japan
关键词
tomography; X-ray computed; radiography; dental;
D O I
10.1038/sj.dmfr.4600448
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To describe a compact computed tomographic apparatus (Ortho-CT) for use in dental practice. Methods: Ortho-CT is a cone-beam-type of CT apparatus consisting of a multifunctional maxillofacial imaging machine (Scanora(R), Soredex, Helsinki, Finland) in which the film is replaced with an X-ray imaging intensifier (Hamamatsu Photonics, Hamamatsu, Japan). The region of image reconstruction is a cylinder 32 mm in height and 38 mm in diameter and the voxel is a 0.136-mm cube. Scanning is at 85 kV and 10 mA with a 1 mm Cu filter. The scan time is 17 s comparable with that required for rotational panoramic radiography. A single scan collects 512 sets of projection data through 360 degrees and the image is reconstructed by a personal computer. The time required for image reconstruction is about 10 min. Results: The resolution limit was about 2.0 lp mm(-1) and the skin entrance dose 0.62 mGy. Excellent image quality was obtained with a tissue-equivalent skull phantom, roots, periodontal ligament space, lamina dura, and cancellous bone were clearly visualized. Conclusion: Ortho-CT provides three-dimensional images of excellent quality for dental use at a low entrance dose.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 17 条
[1]  
AMBROSE J, 1973, BRIT J RADIOL, V46, P148
[2]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .2. CLINICAL APPLICATION [J].
AMBROSE, J .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1023-1047
[3]  
Arai Y, 1998, INT CONGR SER, V1165, P780
[4]  
ARAI Y, 1998, DENT RADIOLOGY S, V38, P51
[5]  
Bianchi SD, 1998, INT CONGR SER, V1165, P792
[6]   RADIATION-DOSE IN RADIOGRAPHY, CT, AND ARTHROGRAPHY OF THE TEMPOROMANDIBULAR-JOINT [J].
CHRISTIANSEN, EL ;
MOORE, RJ ;
THOMPSON, JR ;
HASSO, AN ;
HINSHAW, DB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :107-109
[7]   EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED-TOMOGRAPHY OF THE MAXILLOFACIAL COMPLEX [J].
FREDERIKSEN, NL ;
BENSON, BW ;
SOKOLOWSKI, TW .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (01) :55-58
[8]  
Honda K, 1998, DENTOMAXILLOFAC RA S, V27, P39
[9]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[10]  
Iwai K, 1998, DENTOMAXILLOFAC R S1, V27, P39