Cesium-selective poly(vinylchloride) membrane electrode based on a new calix[4]arene derivative in the 1,3-alternate conformation

被引:17
作者
Arvand-Barmchi, M
Mousavi, MF
Zanjanchi, MA
Taghvaei, S
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] Guilan Univ, Fac Sci, Dept Chem, Rasht IR, Iran
[3] Razi Univ, Fac Sci, Dept Chem, Kermanshah IR, Iran
[4] Univ Tehran, Fac Sci, Dept Chem, Tehran, Iran
关键词
cesium-selective electrode; PVC membrane; 25(3-bromo-propyloxy)-5,11,17,23-tetrakis(tert-butyl)-26,27,28-tris(1-propyloxy) calix[4]arene; 1,3-alternate conformation;
D O I
10.1081/AL-120004064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new calix[4]arene derivative [25-(3-bromo-proploxy)-5,11,-17,23-tetrakis(tert-butyl)-26,27,28-tris(1-propyloxy) calix[4]arene] (BTC) in the 1,3-alternate conformation was tested as a cesium-selective ionophore plasticized PVC membrane electrode. The resulting electrode showed a Nernstian behavior for Cs(+) ion over a wide concentration range (1.0 x 10(-6)-1.0 X 10(-1) M). The selectivity coefficients for cesium with respect to alkali, alkaline earth, ammonium and some transition metal ions, were determined. A relatively high Cs(+)/Rb(+) selectivity was observed, the selectivity coefficient (K(Cs, Rb)(pot)) being ca. 10(-2). Effects of membrane composition and pH of test solution on the potential response of the electrode were also discussed. The proposed electrode revealed a lower limit of detection (2.1 x 10(-7) M) and improved Cs(+)/Rb(+) selectivity in comparison with the previously reported Cs(+) ion selective electrodes.
引用
收藏
页码:767 / 783
页数:17
相关论文
共 42 条
[1]  
ARDUINI A, 1992, NATO ADV SCI I C-MAT, V371, P31
[2]   DOUBLY CROWNED CALIX[4]ARENES IN THE 1,3-ALTERNATE CONFORMATION AS CESIUM-SELECTIVE CARRIERS IN SUPPORTED LIQUID MEMBRANES [J].
ASFARI, Z ;
BRESSOT, C ;
VICENS, J ;
HILL, C ;
DOZOL, JF ;
ROUQUETTE, H ;
EYMARD, S ;
LAMARE, V ;
TOURNOIS, B .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3133-3139
[3]   POTENTIOMETRIC SELECTIVITY STUDY OF TMC-CROWN FORMAZANE IONOPHORE FOR CESIUM [J].
ATTIYAT, AS ;
IBRAHIM, YA ;
CHRISTIAN, GD .
MICROCHEMICAL JOURNAL, 1988, 37 (01) :122-128
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   DETERMINATION OF PARTS-PER-MILLION CESIUM IN SIMULATED NUCLEAR WASTE WITH CESIUM-SELECTIVE ELECTRODE [J].
BAUMANN, EW .
ANALYTICAL CHEMISTRY, 1976, 48 (03) :548-552
[6]   SELECTIVITY OF CALIX[4]ARENE CROWN-6 FOR CESIUM ION IN ISE - EFFECT OF THE CONFORMATION [J].
BOCCHI, C ;
CARERI, M ;
CASNATI, A ;
MORI, G .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4234-4238
[7]   CESIUM-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE ELECTRODES BASED ON CALIX[6]ARENE ESTERS [J].
CADOGAN, A ;
DIAMOND, D ;
SMYTH, MR ;
SVEHLA, G ;
MCKERVEY, MA ;
SEWARD, EM ;
HARRIS, SJ .
ANALYST, 1990, 115 (09) :1207-1210
[8]   SYNTHESIS, COMPLEXATION, AND MEMBRANE-TRANSPORT STUDIES OF 1,3-ALTERNATE CALIX[4]ARENE-CROWN-6 CONFORMERS - A NEW CLASS OF CESIUM SELECTIVE IONOPHORES [J].
CASNATI, A ;
POCHINI, A ;
UNGARO, R ;
UGOZZOLI, F ;
ARNAUD, F ;
FANNI, S ;
SCHWING, MJ ;
EGBERINK, RJM ;
DEJONG, F ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (10) :2767-2777
[9]   RUBIDIUM ION-SELECTIVE ELECTRODE FOR THE ASSAY OF POLYENE ANTIBIOTICS [J].
COSGROVE, RF ;
BEEZER, AE .
ANALYTICA CHIMICA ACTA, 1979, 105 (01) :77-81
[10]  
Cram D.J., 1994, MONOGRAPHS SUPRAMOLE, V4