Application of three-dimensional CT angiography (3D-CTA) to cerebral aneurysms

被引:87
作者
Kato, Y [1 ]
Sano, H
Katada, K
Ogura, Y
Hayakawa, M
Kanaoka, N
Kanno, T
机构
[1] Fujita Hlth Univ, Dept Neurosurg, Aichi 4701192, Japan
[2] Fujita Hlth Univ, Dept Radiol, Aichi 4701192, Japan
来源
SURGICAL NEUROLOGY | 1999年 / 52卷 / 02期
关键词
cerebral aneurysm; three-dimensional CT angiography; surgical simulation; virtual vascular 3D-CT endoscopy;
D O I
10.1016/S0090-3019(99)00062-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND 3D CT angiography (3D-CTA) is a noninvasive imaging modality for cerebral aneurysms. 3D-CTA is helpful in the evaluation of the configuration of the aneurysm, the surrounding vessels, and the inside of the aneurysm dome. Clinical application of this technique in complicated large cerebral aneurysms showed that with 3D-CT endoscopic imaging, anatomical details of cerebral aneurysms such as the orifice of the aneurysm, intraluminal thrombus, and calcification of the wall could be clearly demonstrated. Using the 3D-imaging method with helical CT, virtual views of various surgical approaches can be compared preoperatively, This information was found to be very useful for determining difficult aneurysms for coil embolization or direct surgery including complicated and broad-based aneurysms. METHODS Helical CT scanners (TOSHIBA X-vigor) are used for intracranial vascular lesions. At present, nearly stereoscopic images at a pixel size of 0.35 x 0.35 x 0.4 mm are obtained by reconstruction under the following conditions: slice thickness, 0.8 mm; couch top speed, 1.0 mm/sec.; 130 kV; 220 mA; visual field, 18 cm in diameter (11 cm after extension); pitch, 0.4 mm; and opposed beam interpolation. RESULTS AND CLINICAL APPLICATION By virtual vascular SD-CT endoscopy, the lumen of the cerebral aneurysm is displayed by the surface rendering method. Its clinical applications include 1) Demonstration of three-dimensional aneurysm morphology, including the dome and the neck region; 2) Preoperative simulation; 3) Confirmation of parent blood vessels flowing into and out of aneurysms and visualization of aneurysmal lumen calcification. Coronal and sagittal sections can demonstrate whether the branches arise from the aneurysm or aneurysmal neck. The limitation of 3D-CTA is in delineating perforating arteries that are less than 1.2 mm in diameter, The problem with virtual vascular 3D-CT endoscopic images is that endoscopic findings in the vascular wall are incomplete because of the partial volume effect and pulsation of the aneurysm and vascular wall. CONCLUSIONS Helical Scanning-CT (HES-CT) is an excellent noninvasive diagnostic modality for cerebral aneurysm detection. SD-CT angiography has distinct advantages in evaluating aneurysms and selecting the most appropriate therapeutic modality. (C) 1999 by Elsevier Science Inc.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 10 条
  • [1] Asato M, 1994, J MED IMAG, V14, P679
  • [2] DYNAMIC LOW-DOSE 3-DIMENSIONAL COMPUTED-TOMOGRAPHY - A PRELIMINARY-STUDY
    GHOLKAR, A
    GILLESPIE, JE
    HART, CW
    MOTT, D
    ISHERWOOD, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (732) : 1095 - 1099
  • [3] 3-DIMENSIONAL COMPUTERIZED-TOMOGRAPHY ANGIOGRAPHY IN THE DIAGNOSIS OF CEREBROVASCULAR-DISEASE
    HARBAUGH, RE
    SCHLUSSELBERG, DS
    JEFFERY, R
    HAYDEN, S
    CROMWELL, LD
    PLUTA, D
    [J]. JOURNAL OF NEUROSURGERY, 1992, 76 (03) : 408 - 414
  • [4] 3-DIMENSIONAL COMPUTED TOMOGRAPHIC ANGIOGRAPHY IN THE PREOPERATIVE EVALUATION OF CEREBROVASCULAR LESIONS
    HARBAUGH, RE
    SCHLUSSELBERG, DS
    JEFFERY, R
    HAYDEN, S
    CROMWELL, LD
    PLUTA, D
    ENGLISH, RA
    [J]. NEUROSURGERY, 1995, 36 (02) : 320 - 326
  • [5] Katada K., 1995, Medical Imaging Technology, V13, P208
  • [6] KATADA K, 1991, PHARM MED, V9, P11
  • [7] Kato Y, 1996, NEUROL RES, V18, P98
  • [8] Kobayashi Hisashi, 1992, Nippon Acta Radiologica, V52, P1195
  • [9] OGURA Y, 1996, MED REV, V58, P7
  • [10] Ogura Yuko, 1994, Nippon Acta Radiologica, V54, P965