Preconcentration of uranium(VI) by solid phase extraction onto dicyclohexano-18-crown-6 embedded benzophenone

被引:17
作者
Preetha, CR [1 ]
Rao, TP [1 ]
机构
[1] CSIR, Reg Res Lab, Trivandrum 695019, Kerala, India
关键词
D O I
10.1007/s10967-006-0042-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a solid phase extractant (SPE), dicyclohexano-18-crown-6 embedded benzophenone, for preconcentration of uranium(VI) is described. The uranium(VI) can be quantitatively retained from 0.5 l solution on 1% dicyclohexano-18-crown-6 embedded benzophenone in the pH range 6.0-7.0, and then eluted with 5.0 ml of 1M HCl. Uranium(VI) content of the eluent was determined spectrophotometrically by Arsenazo III. Calibration graphs are rectilinear over the uranium(VI) concentration in the range of 0.004-0.4 mu g(.)mg(-1). Five replicate determinations of 40mg of uranium(VI) present in 0.51 sample gave a mean absorbance of 0.185 with a relative standard deviation of 2.45%. The detection limit corresponding to three times the standard deviation of the blank was found to be 2.0 mu g(.)l(-1). The accuracy of the developed preconcentration procedure was tested by analyzing standard marine sediment reference material. The uranyl ion content of soils and sediments was estimated spectrophotometrically after the preconcentration procedure and compared to the results gained by standard inductively coupled plasma mass spectrometry (ICP-MS).
引用
收藏
页码:265 / 270
页数:6
相关论文
共 37 条
[1]  
[Anonymous], 1970, SOLVENT EXTRACTION M
[2]   On-line trace metal determination by pre-concentration on immobilized 8-quinolinol with flow recycling anodic stripping voltammetry [J].
Armalis, S ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 339 (1-2) :155-159
[3]   Adsorption of metallic cations on silica gel-immobilized 8-hydroxyquinoline [J].
Bernal, JP ;
De San Miguel, ER ;
Aguilar, JC ;
Salazar, G ;
De Gyves, J .
SEPARATION SCIENCE AND TECHNOLOGY, 2000, 35 (10) :1661-1679
[4]  
BHAGAVATHY V, 1989, ANAL LETT, V22, P197
[5]   ENERGY DISPERSIVE-X-RAY FLUORESCENCE (EDXRF) DETERMINATION OF LANTHANIDES AFTER PRECONCENTRATION ON 1-(2-PYRIDYLAZO)-2-NAPHTHOL MODIFIED NAPHTHALENE [J].
BHAGAVATHY, V ;
REDDY, MLP ;
RAO, TP ;
DAMODARAN, AD .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1991, 149 (01) :35-40
[6]   PRECONCENTRATION OF RARE-EARTH QUINOLIN-8-OL COMPLEXES ONTO ACTIVATED CARBON AND DETERMINATION BY 1ST-ORDER DERIVATIVE X-RAY-FLUORESCENCE SPECTROMETRY [J].
BHAGAVATHY, V ;
REDDY, MLP ;
SAI, PST ;
RAO, TP ;
DAMODARAN, AD .
ANALYTICA CHIMICA ACTA, 1991, 242 (02) :215-220
[7]  
Choi HS, 1996, B KOR CHEM SOC, V17, P338
[8]  
DEV K, 1999, TALANTA, V51, P1187
[9]   Solid phase extractive preconcentration of uranium on to 5,7-dichloroquinoline-8-ol modified naphthalene [J].
Gladis, JM ;
Rao, TP .
ANALYTICAL LETTERS, 2002, 35 (03) :501-515
[10]   Quinoline-8-ol-immobilized Amberlite XAD-4: Synthesis, characterization, and uranyl ion uptake properties suitable for analytical applications [J].
Gladis, JM ;
Rao, TP .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) :867-872