Performance study of a microturbine system for cogeneration application

被引:73
作者
Ho, JC [1 ]
Chua, KJ [1 ]
Chou, SK [1 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, Singapore 117576, Singapore
关键词
cogeneration; absorption chiller; system performance;
D O I
10.1016/j.renene.2003.12.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A microturbine cogeneration system providing electrical power and space cooling to a laboratory space is presented. The system comprises a microturbine, a lithium bromide absorption chiller, heat exchangers and a propane fuel supply system. Results from the performance tests conducted on the cogeneration system showed that the microturbine electrical efficiency was 21% at near full load of 24 kW whilst the chiller operated with COP ranging from 0.5 to 0.58, depending on the electrical output. The overall system efficiency ranged from 40% to 49%. In addition, the performance of the cogeneration system under varying heat load in the cooling space and longer microturbine operating period were also studied. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1121 / 1133
页数:13
相关论文