Potential value of dual-time-point 18F-FDG PET compared with initial single-time-point imaging in differentiating malignant from benign pulmonary nodules: a systematic review and meta-analysis

被引:32
作者
Lin, Yu-Yi [1 ,2 ]
Chen, Jin-Hua [4 ,5 ]
Ding, Hueisch-Jy [8 ]
Liang, Ji-An [3 ,6 ,7 ]
Yeh, Jun-Jun [6 ,7 ,8 ,9 ]
Kao, Chia-Hung [1 ,2 ,3 ]
机构
[1] China Med Univ, Coll Med, Dept Nucl Med, Taichung, Taiwan
[2] China Med Univ, PET Ctr, Coll Med, Taichung, Taiwan
[3] China Med Univ, Dept Radiat Oncol, Coll Med, Taichung, Taiwan
[4] China Med Univ, Ctr Biostat, Coll Med, Taichung, Taiwan
[5] China Med Univ, Grad Inst Biostat, Coll Med, Taichung, Taiwan
[6] China Med Univ, Coll Med, Grad Inst Clin Med Sci, Taichung, Taiwan
[7] China Med Univ, Coll Med, Sch Med, Taichung, Taiwan
[8] I Shou Univ, Dept Med Imaging & Radiol Sci, Kaohsiung, Taiwan
[9] Chia Nan Univ Pharm & Sci, Tainan, Taiwan
关键词
dual-time-point imaging; F-18-fluorodeoxyglucose; meta-analysis; positron emission tomography; pulmonary nodules; STANDARDIZED UPTAKE VALUES; FDG-PET; PROCEDURE GUIDELINE; LUNG-CANCER; BODY-WEIGHT; LESIONS; FLUORODEOXYGLUCOSE; HETEROGENEITY; DIAGNOSIS; ACCUMULATION;
D O I
10.1097/MNM.0b013e32835710d6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We performed a meta-analysis to assess the potential value of dual-time-point (DTP) imaging as compared with initial single-time-point (STP) scanning with F-18-fluorodeoxyglucose (F-18-FDG) PET in differentiating malignant from benign single pulmonary nodules. Data on the performance of DTP F-18-FDG PET imaging in assessing lung nodules were extracted from articles of prospective or retrospective original research published between January 2001 and April 2010. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool was used to assess the quality of study methodology. Heterogeneity in the results of the studies was assessed, and summary receiver operating characteristic (SROC) curves were constructed. Eleven studies comprising a total of 788 patients who underwent initial scanning, 778 of whom also underwent DTP imaging, were included in the final analysis. The quality of study methodology was judged to be moderate. Substantial heterogeneity in the results of the studies, with inconsistency (I-2) index values above 85%, reflected important differences in study methods and populations, including varying lesion sizes, F-18-FDG avidity, uptake interval for delayed imaging, and threshold for positive result on DTP imaging. SROC curve analysis revealed a statistically nonsignificant trend toward higher sensitivity with DTP imaging, at moderate levels of specificity, when compared with initial SIP scanning. The area under the curve (SE) values for DTP and initial SIP imaging were 0.839 (0.079) and 0.757 (0.074), respectively. Although the results of our analysis do not support the routine use of DTP imaging with F-18-FDG PET in the differential diagnosis of pulmonary nodules, this technique may provide additional information in selected cases with eqiivocal results from initial scanning. Further prospective research is required to better define the potential benefits of DTP F-18-FDG PET imaging. Nucl Med Commun 33:1011-1018 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1011 / 1018
页数:8
相关论文
共 37 条
[1]   Impact of dual-time-point 18F-FDG PET imaging and partial volume correction in the assessment of solitary pulmonary nodules [J].
Alkhawaldeh, Khaled ;
Bural, Gonca ;
Kumar, Rakesh ;
Alavi, Abass .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (02) :246-252
[2]  
[Anonymous], REV ESP MED NUCL
[3]   Diagnostic Performance of Dual-time 18F-FDG PET in the Diagnosis of Pulmonary Nodules: A Meta-analysis [J].
Barger, Richard L., Jr. ;
Nandalur, Kiran R. .
ACADEMIC RADIOLOGY, 2012, 19 (02) :153-158
[4]  
Basu S, 2009, Q J NUCL MED MOL IM, V53, P9
[5]   Dual-phase 18F-FDG PET in the diagnosis of pulmonary nodules with an initial standard uptake value less than 2.5 [J].
Chen, Chao-Jung ;
Lee, Bi-Fang ;
Yao, Wei-Jen ;
Cheng, Lili ;
Wu, Pei-Shan ;
Chu, Ching Lin ;
Chiu, Nan-Tsing .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :475-479
[6]   Limitations of dual time point PET in the assessment of lung nodules with low FDG avidity [J].
Cloran, Francis J. ;
Banks, Kevin P. ;
Song, Won S. ;
Kim, Young ;
Bradley, Yong C. .
LUNG CANCER, 2010, 68 (01) :66-71
[7]   Narrow time-window dual-point 18F-FDG PET for the diagnosis of thoracic malignancy [J].
Conrad, GR ;
Sinha, P .
NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (11) :1129-1137
[8]  
Delbeke D, 2006, J NUCL MED, V47, P885
[9]  
Demura Y, 2003, J NUCL MED, V44, P540
[10]   A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy [J].
Dinnes, J ;
Deeks, J ;
Kirby, J ;
Roderick, P .
HEALTH TECHNOLOGY ASSESSMENT, 2005, 9 (12) :1-+