In vivo response of porous hydroxyapatite and β-tricalcium phosphate prepared by aqueous solution combustion method and comparison with bioglass scaffolds

被引:116
作者
Ghosh, Samir K. [1 ]
Nandi, Samit K. [2 ]
Kundu, Biswanath [1 ]
Datta, Someswar [1 ]
De, Dipak K. [2 ]
Roy, Sujit K. [1 ]
Basu, Debabrata [1 ]
机构
[1] Cent Glass & Ceram Res Inst, Kolkata, India
[2] W Bengal Univ Anim & Fishery Sci, Kolkata, India
关键词
solution combustion; calcium phosphate; bioglass; push-out test; vascularization;
D O I
10.1002/jbm.b.31009
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Pure hydroxyapatite (HAp) and a biphasic calcium phosphate [containing 90% of beta-tri-calcium phosphate (beta-TCP) and 10% HAp] were tailored through an aqueous solution combustion synthesis. Porous struts were prepared using all the powders along with bioglass, a known bioactive material, and subsequently characterized. Sterilized struts were implanted to the lateral side of radius bone of 24 black Bengal goats of either sex, in which a blank hole was left unfilled in a group of six specimens to act as control. The bone formation response of the three implanting materials in vivo has been studied using scanning electron microscope and histological analysis in contrast with positive controls. Push-out tests were used to assess the mechanical strength at the bone-biomaterial interface. It was observed that interfacial response was strongly dependent on combinations of different physical and chemical parameters. The surface of beta-TCP exhibited similar characteristics of bone and was distinct from those of intervening apatite layer of bioglass. Lower bone ingrowth and reduced strength was observed with HAp compared to beta-TCP/bioglass-based implants. Bone formation response of the Ca-P material varied according to the composition of the implanting material, which could be tailored through this novel synthesis. (C) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 44 条
[1]
ALEXANDER H, 1987, CRIT REV BIOCOMPAT, V4, P43
[2]
Porosity variation in hydroxyapatite and osteoblast morphology: a scanning electron microscopy study [J].
Annaz, B ;
Hing, KA ;
Kayser, M ;
Buckland, T ;
Di Silvio, L .
JOURNAL OF MICROSCOPY, 2004, 215 :100-110
[3]
Asada M., 1987, Yogyo-Kyokai-Shi, V95, P703, DOI 10.2109/jcersj1950.95.1103_703
[4]
A COMPARISON OF HOST RESPONSE TO CORTICAL AUTOGRAFTS AND PROCESSED CALF HETEROGRAFTS [J].
BASSETT, CAL ;
CREIGHTON, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (05) :842-854
[5]
Effect of micro- and macroporosity of bone substitutes on their mechanical properties and cellular response [J].
Bignon, A ;
Chouteau, J ;
Chevalier, J ;
Fantozzi, G ;
Carret, JP ;
Chavassieux, P ;
Boivin, G ;
Melin, M ;
Hartmann, D .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (12) :1089-1097
[6]
THE USE OF DEMINERALIZED BONE-MATRIX IN THE REPAIR OF SEGMENTAL DEFECTS - AUGMENTATION WITH EXTRACTED MATRIX PROTEINS AND A COMPARISON WITH AUTOLOGOUS GRAFTS [J].
BOLANDER, ME ;
BALIAN, G .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (08) :1264-1274
[7]
Osteoconduction in large macroporous hydroxyapatite ceramic implants: Evidence for a complementary integration and disintegration mechanism [J].
Boyde, A ;
Corsi, A ;
Quarto, R ;
Cancedda, R ;
Bianco, P .
BONE, 1999, 24 (06) :579-589
[8]
OSSEOINTEGRATED TITANIUM FIXTURES IN THE TREATMENT OF EDENTULOUSNESS [J].
BRANEMARK, PI ;
ADELL, R ;
ALBREKTSSON, T ;
LEKHOLM, U ;
LUNDKVIST, S ;
ROCKLER, B .
BIOMATERIALS, 1983, 4 (01) :25-28
[9]
Chang CS, 1999, J BIOMED MATER RES, V48, P411, DOI 10.1002/(SICI)1097-4636(1999)48:4<411::AID-JBM3>3.0.CO
[10]
2-H