Electrochemical removal of nitrate ions in waste solutions after regeneration of ion exchange columns

被引:102
作者
Paidar, M [1 ]
Rousar, I [1 ]
Bouzek, K [1 ]
机构
[1] Inst Chem Technol, Dept Inorgan Technol, CR-16628 Prague 6, Czech Republic
关键词
drinking water; electrochemical nitrate ion reduction; ion exchange column;
D O I
10.1023/A:1026423218899
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Electrochemical reduction of nitrate ions in synthetic regenerating solutions after ion exchange column regeneration was studied. The influence of current density on the current efficiency was determined in the range 2.8-7.6 mA cm(-2) in a diaphragmless flow-through electrolyser in a batch recirculation mode. A Cu cathode and a Ti/Pt anode was used, the temperature being maintained at 25 degrees C. Highest integral current efficiency occurred at 2.8 mA cm(-2). The presence of about 6 mg dm(-3) Cu ions in treated solution was found to prevent a decrease in cathode activity and, consequently, in electrolysis efficiency. The catalytic influence of Cu ions was verified by potentiodynamic polarisation experiments on a copper rotating disc electrode and by chronopotentiometry performed during the course of electrolysis.
引用
收藏
页码:611 / 617
页数:7
相关论文
共 28 条