Variability in Anticoagulation Management of Patients on Extracorporeal Membrane Oxygenation: An International Survey

被引:303
作者
Bembea, Melania M. [1 ,2 ]
Annich, Gail [3 ]
Rycus, Peter [4 ]
Oldenburg, Gary [1 ]
Berkowitz, Ivor [1 ,2 ]
Pronovost, Peter [1 ]
机构
[1] Johns Hopkins Univ, Dept Anesthesiol & Crit Care, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Pediat, Baltimore, MD 21218 USA
[3] Univ Michigan, Dept Pediat, Ann Arbor, MI 48109 USA
[4] Extracorporeal Life Support Org, Ann Arbor, MI USA
基金
美国国家卫生研究院;
关键词
anticoagulation; anti-factor Xa; antithrombin; extracorporeal membrane oxygenation; thromboelastography; ACTIVATED CLOTTING TIME; CARDIOPULMONARY BYPASS; COAGULATION MANAGEMENT; ANTITHROMBIN-III; HEPARIN; PLASMA; ECMO; STANDARD; CHILDREN; INFANTS;
D O I
10.1097/PCC.0b013e31827127e4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The objective of this study was to determine current practices of anticoagulation in patients on extracorporeal membrane oxygenation. Design: Internet-based cross-sectional survey distributed between November 2010 and May 2011. Setting: Extracorporeal Life Support Organization-registered extracorporeal membrane oxygenation centers internationally. Participants: Extracorporeal membrane oxygenation medical directors and coordinators. Interventions: None. Measurements and Main Results: There were 121 responses from extracorporeal membrane oxygenation medical directors and coordinators at 187 Extracorporeal Life Support Organization centers with access to the survey. Eighty-four of 117 (72%) respondents reported having a written institutional extracorporeal membrane oxygenation protocol for both anticoagulation and blood product management at their institutions. Sixty-nine of 117 (59%) respondents reported use of tip-to-tip or partially heparin-bonded circuits. Unfractionated heparin was used at all centers; only 8% of respondents indicated use of alternative anticoagulation medications in the six months prior to the survey. The preferred method of anticoagulation monitoring was the serial measurement of activated clotting time, as reported by 97% of respondents. In this survey, 82% of respondents reported antithrombin III testing, 65% reported anti-factor Xa testing, and 43% reported use of thromboelastography during extracorporeal membrane oxygenation. Goal ranges for these three tests and interventions triggered by out-of-range values were found to be variable. Conclusions: Extracorporeal membrane oxygenation anticoagulation management policies vary widely by center. The majority of extracorporeal membrane oxygenation programs employ activated clotting time as the preferred anticoagulation monitoring tool. The coagulation system is also monitored using more specific markers such as antithrombin III, anti-factor Xa, and thromboelastography by a large number of centers. Future research is needed to elucidate optimal anticoagulation management and improve outcomes. (Pediatr Crit Care Med 2013; 14:e77-e84)
引用
收藏
页码:E77 / E84
页数:8
相关论文
共 33 条
[1]   Use of a novel anticoagulation strategy during ECMO in a pediatric population:: Single-center experience [J].
Agati, Salvatore ;
Ciccarello, Giuseppe ;
Salvo, Dario ;
Turla, Giancarlo ;
Uendar, Akif ;
Mignosa, Carmelo .
ASAIO JOURNAL, 2006, 52 (05) :513-516
[2]   Coagulation factor activity during neonatal extra-corporeal membrane oxygenation [J].
Arnold, P ;
Jackson, S ;
Wallis, J ;
Smith, J ;
Bolton, D ;
Haynes, S .
INTENSIVE CARE MEDICINE, 2001, 27 (08) :1395-1400
[3]  
Chan AKC, 1997, THROMB HAEMOSTASIS, V77, P270
[4]  
Colby Christopher E, 2003, J Extra Corpor Technol, V35, P35
[5]   Extracorporeal Life Support Registry Report 2004 [J].
Conrad, SA ;
Rycus, PT ;
Dalton, H .
ASAIO JOURNAL, 2005, 51 (01) :4-10
[6]  
Despotis GJ, 1996, THROMB HAEMOSTASIS, V76, P902
[7]   Coagulation management in pediatric mechanical circulatory support [J].
Drews, Thorsten ;
Stiller, Brigitte ;
Huebler, Michael ;
Weng, Yuguo ;
Berger, Felix ;
Hetzer, Roland .
ASAIO JOURNAL, 2007, 53 (05) :640-645
[8]   Avecor trillium oxygenator versus noncoated monolyth oxygenator: A prospective randomized controlled study [J].
Eynden, Frederic Vanden ;
Carrier, Michel ;
Ouellet, Sandra ;
Demers, Philippe ;
Forcillo, Jessica ;
Perrault, Louis P. ;
Pellerin, Michel ;
Bouchard, Denis .
JOURNAL OF CARDIAC SURGERY, 2008, 23 (04) :288-293
[9]   Maintaining the standard: A quality assurance study for new equipment in the Michigan ECMO program [J].
Fleming, Geoffrey M. ;
Gupta, Monika ;
Cooley, Elaine ;
Remenapp, Robert ;
Bartlett, Robert H. ;
Annich, Gail M. .
ASAIO JOURNAL, 2007, 53 (05) :556-560
[10]   Anticoagulation practices during neonatal extracorporeal membrane oxygenation: survey results [J].
Graves, Donna F. ;
Chernin, Jill M. ;
Kurusz, Mark ;
Zwischenberger, Joseph B. .
PERFUSION-UK, 1996, 11 (06) :461-466