Pump Exchange for Cable Damage in Patients Supported With HeartMate II Left Ventricular Assist Device

被引:21
作者
Potapov, Evgenij V. [1 ]
Kaufmann, Friedrich [1 ]
Stepanenko, Alexander [1 ]
Hening, Ewald [1 ]
Vierecke, Juliane [1 ]
Loew, Alexandra [1 ]
Lehmkuhl, Elke [1 ]
Dranishnikov, Nikolay [1 ]
Hetzer, Roland [1 ]
Krabatsch, Thomas [1 ]
机构
[1] Deutsch Herzzentrum Berlin, D-13353 Berlin, Germany
关键词
HeartMate II; left ventricular assist device; exchange; cable damage;
D O I
10.1097/MAT.0b013e3182703718
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Implantable continuous flow pumps are a routine treatment for end-stage heart failure. The waiting time for heart transplantation is increasing, and more and more patients receive the pump for permanent support. We retrospectively analyzed our database of patients supported with the HeartMate II left ventricular assist device to identify instances of cable damage. Between May 9, 2006 and May 9, 2012, 161 patients were supported with the HeartMate II. There were 187 cumulative years of HeartMate II support. The documented cable damage occurred in 12 patients (7.5%), requiring pump exchange in five patients after a mean time of 706 days on support. There was no perioperative mortality. The damage occurred typically at the "weak" place-the feedthrough of the driveline to the pump body. In some cases, the device alarm history and x-ray may allow diagnosis before pump stop occurs. However, since the most recent changes in the design of the connection and modifications made in the implantation technique, no instance of cable damage has been registered. ASAIO Journal 2012;58:578-582.
引用
收藏
页码:578 / 582
页数:5
相关论文
共 4 条
[1]
Technique for Less Invasive Implantation of Heartmate II Left Ventricular Assist Device Without Median Sternotomy [J].
Anyanwu, Anelechi C. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2011, 23 (03) :241-244
[2]
Minimally invasive, off-pump explant of a continuous-flow left ventricular assist device [J].
Cheung, Anson ;
Bashir, Jamil ;
Kaan, Annemarie ;
Kealy, Jennifer ;
Moss, Robert ;
Shayan, Hossein .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (07) :808-810
[3]
A felt plug simplifies left ventricular assist device removal after successful bridge to recovery [J].
Cohn, William E. ;
Gregoric, Igor D. ;
Radovancevic, Branislav ;
Frazier, O. H. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (11) :1209-1211
[4]
Successful Weaning and Explantation of the Heartmate II Left Ventricular Assist Device [J].
Lamarche, Yoan ;
Kearns, Mark ;
Josan, Kiranbir ;
Bashir, Jamil ;
Ignaszewski, Andrew ;
Kaan, Annemarie ;
Kealy, Jennifer ;
Moss, Robert ;
Cheung, Anson .
CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (03) :358-362