Diagnostic accuracy of an international static-imaging telepathology consultation service

被引:114
作者
Halliday, BE
Bhattacharyya, AK
Graham, AR
Davis, JR
Leavitt, SA
Nagle, RB
McLaughlin, WJ
Rivas, RA
Martinez, R
Krupinski, EA
Weinstein, RS
机构
[1] UNIV ARIZONA, DEPT PATHOL, TUCSON, AZ 85724 USA
[2] UNIV ARIZONA, DEPT RADIOL, TUCSON, AZ 85724 USA
[3] UNIV ARIZONA, DEPT ELECT ENGN & COMP ENGN, TUCSON, AZ USA
[4] UNIV ARIZONA, ARIZONA TELEMED PROGRAM, TUCSON, AZ USA
关键词
telepathology; telemedicine; static imaging; dynamic-robotic imaging; histological diagnosis; diagnostic accuracy;
D O I
10.1016/S0046-8177(97)90273-2
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Static-image and dynamic- (real-time) image telepathology are competing. technologies. Although some studies suggest that the diagnostic accuracy of the dynamic-image telepathology approaches the accuracy of light microscopy, few reports have documented the diagnostic accuracy of static-image telepathology as used in the setting of an actual surgical pathology consultation practice. We report the results of an analysis of 171 telepathology consultation cases submitted to the Arizona-International Telemedicine Network (AITN). Digital images were submitted by pathologists from six participating institutions in Arizona, Mexico and China. Telepathologists could render a telepathology diagnosis (TP) or defer rendering a diagnosis to obtain additional video images, glass slides for detailed analysis, or to obtain tissue blocks for special studies such as immunohistochemistry. The telepathologists rendered diagnoses for 144 cases and deferred 27 cases. Two pathologists retrospectively evaluated glass slides from each case and rendered a consensus glass slide (GS) ''truth'' diagnosis. There was 88.2% concordance between TP and GS diagnoses (127 of 144 diagnoses). Concordance of 96.5% was achieved for clinically important diagnoses (139 of 144 diagnoses). Telepathologists deferred making a diagnosis to obtain glass slides for conventional light microscopy in 14 cases (8.1%) and for results of immunohistochemistry studies in 13 cases (7.6%). Thus, correct diagnoses were rendered by static-image telepathology in 127 of 171 cases (74.3%) at the time of telepathology diagnostic sessions. Inappropriate field selection and sampling biases of referring pathologists, as well as a tendency of static-image telepathologists to underestimate the complexity of some cases, may reduce the value of consultations based on the viewing of static images. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 29 条
[1]   USE OF REMOTE VIDEO MICROSCOPY (TELEPATHOLOGY) AS AN ADJUNCT TO NEUROSURGICAL FROZEN-SECTION CONSULTATION [J].
BECKER, RL ;
SPECHT, CS ;
JONES, R ;
RUEDAPEDRAZA, ME ;
OLEARY, TJ .
HUMAN PATHOLOGY, 1993, 24 (08) :909-911
[2]  
Bhattacharyya A K, 1995, Telemed J, V1, P9, DOI 10.1089/tmj.1.1995.1.9
[3]  
Black-Schaffer S, 1995, Telemed J, V1, P95, DOI 10.1089/tmj.1.1995.1.95
[4]   NEPHROPATHOLOGY CONSULTATION VIA DIGITIZED IMAGES [J].
CRONENBERGER, JH ;
HSIAO, H ;
FALK, RJ ;
JENNETTE, JC .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1992, 670 :281-292
[5]   Dynamic-robotic telepathology: Department of veterans affairs feasibility study [J].
Dunn, BE ;
Almagro, UA ;
Choi, HY ;
Sheth, NK ;
Arnold, JS ;
Recla, DL ;
Krupinski, EA ;
Graham, AR ;
Weinstein, RS .
HUMAN PATHOLOGY, 1997, 28 (01) :8-12
[6]   CURRENT STATUS OF TELEPATHOLOGY [J].
EIDE, TJ ;
NORDRUM, I .
APMIS, 1994, 102 (12) :881-890
[7]  
Eide Tor J., 1992, Zentralblatt fuer Pathologie, V138, P409
[8]  
ITO H, 1994, MODERN PATHOL, V7, P801
[9]  
Kayser K., 1992, Zentralblatt fuer Pathologie, V138, P395
[10]  
Kayser K, 1993, In Vivo, V7, P395