Measurement of Mandible Movements Using a Vernier Caliper - An Evaluation of the Intrasession-, Intersession- and Interobserver Reliability

被引:16
作者
Best, Norman [1 ]
Best, Stefanie [2 ]
Loudovici-Krug, Dana [3 ]
Smolenski, Ulrich C. [2 ,4 ]
机构
[1] Jena Univ Hosp, Therapy & Rehabil Ctr, D-07740 Jena, Germany
[2] Jena Univ Hosp, Inst Physiotherapy, D-07740 Jena, Germany
[3] Lubinus Sch Kiel, Kiel, Germany
[4] Univ Jena, Fac Med, D-07745 Jena, Germany
来源
CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE | 2013年 / 31卷 / 03期
关键词
D O I
10.1179/crn.2013.028
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
The aim of this study was to evaluate the intrasession-, intersession-, and interrater reliability of a vernier caliper measurement of mandible movements. The authors calculated the intrasession, intersession-, and interrater reliability using a plastic caliper for important mandibular parameters. All intraclass-correlation-coefficients (ICC) are at least moderately accurate, especially the values for intrasession- and intersession reliability, which were excellent. Only the interrater reliability shows greater fluctuations. Whereas the mouth opening, protrusion, and the tooth positions are reliably correct, the same was not applicable to the side movements. The lateral movement measurements were highly variable. This did not apply to other movements. Patient compliance is important along with a different mouth-opening angle. It is possible to generate a variable laterotrusion to both sides. The caliper investigated is a fast, simple, and inexpensive tool for daily work.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 13 条
[1]
Best N, 2010, THESIS FRIEDRICH SCH
[2]
Buhl A, 2008, 16 SPSS
[3]
Identification of candidate categories of the International Classification of Functioning Disability and Health (ICF) for a Generic ICF Core Set based on regression modelling [J].
Cieza A. ;
Geyh S. ;
Chatterji S. ;
Kostanjsek N. ;
Üstün B.T. ;
Stucki G. .
BMC Medical Research Methodology, 6 (1)
[4]
Reliability of measuring active mandibular excursion using a new tool: The mandibular excursiometer [J].
Danis, CG ;
Mielenz, TJ .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1997, 25 (03) :213-219
[5]
ASSESSING CLINICAL SIGNS OF TEMPOROMANDIBULAR DISORDERS - RELIABILITY OF CLINICAL EXAMINERS [J].
DWORKIN, SF ;
LERESCHE, L ;
DEROUEN, T ;
VONKORFF, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 63 (05) :574-579
[6]
ICF in rehabilitation [J].
Ewert, T ;
Cieza, A ;
Stucki, G .
PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2002, 12 (03) :157-162
[7]
HARTUNG J, 1999, STAT LEHR HDB ANGEW
[8]
Jungling N., 2004, MANUELLE MED, V42, P441
[9]
MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]
Ruge S, 2012, INT J COMPUT DENT, V14, P119