Can radiofrequency current isthmus ablation damage the right coronary artery? Histopathological findings following the use of a long (8 mm) tip electrode

被引:28
作者
Weiss, C
Becker, J
Hoffmann, M
Willems, S
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20251 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Dept Pathol, D-20251 Hamburg, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2002年 / 25卷 / 05期
关键词
catheter ablation; atrial flutter; histopathology;
D O I
10.1046/j.1460-9592.2002.00860.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This report describes the histopathological findings following successful RF isthmus ablation for common atrial flutter in a 68-years-old man using a long 8-mm tip ablation catheter. No acute complication was observed. The patient died 3 weeks after ablation due to severe heart failure and consecutive pneumonia. Lesion width (1.0 and 2.4 cm) and depth (0.4 and 0.8 cm) was measured. The right coronary artery showed an intramural hemorrhage adjacent to the side of the lesion. However, despite this finding no apparent injury of other layers of the coronary artery was detectable.
引用
收藏
页码:860 / 862
页数:3
相关论文
共 8 条
[1]   Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation [J].
Jaïs, P ;
Haïssaguerre, M ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Lavergne, T ;
Lafitte, S ;
Le Mouroux, A ;
Fischer, B ;
Clémenty, J .
CIRCULATION, 1998, 98 (09) :835-838
[2]   TEMPERATURE-GUIDED RADIOFREQUENCY CATHETER ABLATION WITH VERY LARGE DISTAL ELECTRODES [J].
LANGBERG, JJ ;
GALLAGHER, M ;
STRICKBERGER, SA ;
AMIRANA, O .
CIRCULATION, 1993, 88 (01) :245-249
[3]   RADIOFREQUENCY CATHETER ABLATION - THE EFFECT OF ELECTRODE SIZE ON LESION VOLUME INVIVO [J].
LANGBERG, JJ ;
LEE, MA ;
CHIN, MC ;
ROSENQVIST, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (10) :1242-1248
[4]   Coronary artery involvement early and late after radiofrequency current application in young pigs [J].
Paul, T ;
Bokenkamp, R ;
Mahnert, B ;
Trappe, HJ .
AMERICAN HEART JOURNAL, 1997, 133 (04) :436-440
[5]   Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium - Impact of ablation site, electrode size, and convective cooling [J].
Petersen, HH ;
Chen, X ;
Pietersen, A ;
Svendsen, JH ;
Haunso, S .
CIRCULATION, 1999, 99 (02) :319-325
[6]   EFFECT ON CORONARY-ARTERY ANATOMY OF RADIOFREQUENCY CATHETER ABLATION OF ATRIAL INSERTION SITES OF ACCESSORY PATHWAYS [J].
SOLOMON, AJ ;
TRACY, CM ;
SWARTZ, JF ;
REAGAN, KM ;
KARASIK, PE ;
FLETCHER, RD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) :1440-1444
[7]   Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter? [J].
Tsai, CF ;
Tai, CT ;
Yu, WC ;
Chen, YJ ;
Hsieh, MH ;
Chiang, CE ;
Ding, YA ;
Chang, MS ;
Chen, SA .
CIRCULATION, 1999, 100 (07) :768-771
[8]   Right atrial flutter isthmus revisited: Normal anatomy favors nonuniform anisotropic conduction [J].
Waki, K ;
Saito, T ;
Becker, AE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (01) :90-94