Mapping a topographic global solar radiation model implemented in a GIS and refined with ground data

被引:77
作者
Pons, Xavier [2 ,3 ]
Ninyerola, Miquel [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Biol Anim Biol Vegetal & Ecol, Catalonia, Spain
[2] Univ Autonoma Barcelona, Dept Geog, Catalonia, Spain
[3] Univ Autonoma Barcelona, Ctr Ecol Res & Forest Applicat, Catalonia, Spain
关键词
potential solar radiation; interpolated solar radiation; Catalonia (NE of Iberian Peninsula); spatial interpolation; climatological modelling; sensitivity analysis;
D O I
10.1002/joc.1676
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
This study proposes a methodology to compute solar radiation values on the Earth surface on a monthly and annual basis and taking into account the relief, which is not an usual approach although it has enormous importance for environmental studies. It consists of two steps: a computational, physically-based model (potential solar radiation) and a refining through meteorological data (interpolated solar radiation). The potential solar radiation model allows computing the incident energy assuming uniform atmospheric standard optical density. The only information required is a Digital Elevation Model (DEM, 180 m resolution in our case) and a number of meteorological stations providing global solar radiation data (74 in our case). This model, implemented into the MiraMon Geographic Information System (GIS), takes into account astronomical, atmospheric and geographical factors. Atmospheric effects are considered through correctors obtained by comparing the potential values with the observed at the meteorological stations. The resulting monthly correctors have been spatially interpolated to build up anomaly maps, which allow to obtain a refined solar radiation cartography. The potential model has proven to be very precise as it gives results close to the interpolated radiation values, allowing a conversion to interpolated solar radiation maps with errors of 7.3% (March), 6.1% (June), 6.4% (September) and 13.1% (December) computed from a leave-one-out cross-validation. These results are always better than those obtained by classical interpolators, and still better if the process is run on the rugged terrain areas. A sensitivity analysis estimates the influence of the DEM quality on the model, concluding that an RMS error of 8 m in the DEM heights represents an RMS error of 133 kJ.m(-2).day(-1) (mean monthly) on the results. Finally, we have applied the model to obtain the 12-monthly (based on daily average) global solar radiation maps of Catalonia (NE of Iberian Peninsula) as well as the annual one. Copyright (c) 2008 Royal Meteorological Society
引用
收藏
页码:1821 / 1834
页数:14
相关论文
共 97 条
[1]   Estimation of solar radiation from the number of sunshine hours [J].
Ampratwum, DB ;
Dorvlo, ASS .
APPLIED ENERGY, 1999, 63 (03) :161-167
[2]  
[Anonymous], 2000, TERRAIN ANAL PRINCIP
[3]  
[Anonymous], 7 C GEOGR CUANT SIST
[4]  
[Anonymous], GOTTINGER GEOGRAPHIS
[5]   Modelling daily topographic solar radiation without site-specific hourly radiation data [J].
Antonic, O .
ECOLOGICAL MODELLING, 1998, 113 (1-3) :31-40
[7]  
BALDASANO JM, 1994, ATLAS RADIACIO SOLAR
[8]  
Bariou R., 1986, CORRECTIONS RADIOMET
[9]   Statistical comparison of models for estimating the monthly average daily diffuse radiation at a subtropical African site [J].
Bashahu, M .
SOLAR ENERGY, 2003, 75 (01) :43-51
[10]   ON SHADOWBAND CORRECTION METHODS FOR DIFFUSE IRRADIANCE MEASUREMENTS [J].
BATLLES, FJ ;
OLMO, FJ ;
ALADOSARBOLEDAS, L .
SOLAR ENERGY, 1995, 54 (02) :105-114