Validation up-date

被引:8
作者
O'Brien, E [1 ]
机构
[1] Beaumont Hosp, Blood Pressure Unit, Dublin 9, Ireland
[2] Beaumont Hosp, ADAPT Ctr, Dublin 9, Ireland
关键词
protocol; device validation; blood pressure; blood pressure measurement; British Hypertension Society (BHS); Association for the Advancement of Medical Instrumentation (AAMI);
D O I
10.1097/00126097-200112000-00002
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
With the increasing marketing of automated and semi-automated devices for the measurement of blood pressure, there is a need for potential purchasers to be able to satisfy themselves that such devices have been evaluated according to agreed criteria. Since their introduction a large number of blood pressure measuring devices have been evaluated according to one or both protocols. However, experience has demonstrated that the conditions demanded by the protocols are extremely difficult to fulfil, The European Society of Hypertension (ESH) protocol, named the International Protocol, which will be published shortly, is based on the data from 19 validation studies performed according to the AAMI and BHS protocols. Critical assessment of this data base of evidence has permitted rationalisation and simplification of validation procedures without loosing the merits of the much more complicated earlier protocols. This has been achieved by elimination of pre-validation phases, improving observer recruitment and training, minimising observer error during validation, reducing the number of subjects recruited, relaxing the range of blood pressures required and eliminating 'hopeless' devices early in the validation procedure. (C) 2001 Lippincott Williams Wilkins.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 37 条
[1]  
[Anonymous], 1987, NAT STAND EL AUT SPH
[2]   Guidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus conference [J].
Asmar, R ;
Zanchetti, A .
JOURNAL OF HYPERTENSION, 2000, 18 (05) :493-508
[3]  
Association for the Advancement of Medical Instrumentation, 1993, AM NAT STAND EL AUT
[4]  
Atkins, 1997, Blood Press Monit, V2, P269
[5]  
*BRIT HYP SOC, 1998, BLOOD PRESS MEAS
[6]  
*EUR COMM STAND, 1995, 10602 EN EUR COMM 2
[7]  
*EUR COMM STAND, 1997, 10603 EN EUR COMM 3
[8]  
*EUR COMM STAND, 1995, 10601 EN EUR COMM 1
[9]  
*EUR COMM STAND, 1993, 540 EN EUR COMM STAN
[10]   24-HOUR AMBULATORY BLOOD-PRESSURE MEASUREMENT IN A PRIMIGRAVID POPULATION [J].
HALLIGAN, A ;
OBRIEN, E ;
OMALLEY, K ;
MEE, F ;
ATKINS, N ;
CONROY, R ;
WALSHE, JJ ;
DARLING, M .
JOURNAL OF HYPERTENSION, 1993, 11 (08) :869-873